TRAINING EQUIPMENT FOR “SAFETY MULTI-BOX”
8025381/2020-07-14
SHORT OPERATING INSTRUCTIONS |”SAFETY MULTI-BOX” TRAINING EQUIP+DEMOCASE
SICK AG | Waldkirch | Germany | www.sick.com
6
Safety function
Initiated by
To reset the safety
function
Note
Example applications
Initiating stop and
preventing start
Intrusion into the protective field
of the safety laser scanner
(detection of an object with a
diameter of approx. 30 mm or
greater)
Clear the protective field
+ press the Reset button
Operating mode 0, 1
When an object enters the warning
field, the indicator
switches to
yellow. The safety function is not
triggered.
When an object enters the protective
field, the indicator
switches to red
Non-contact protection with
proximity function
Initiating a stop
Intrusion into the protective field
of the safety light curtain
(detection of an object of size
14 mm or greater)
Clear the protective field
+ press the Reset button
Operating mode 0, 1
When an object enters the protective
field, the indicator
switches to
red.
Non-contact protection with
proximity function
Protection for automated
material transport
Warning
field
Protective
field
105
210
445
300
26
11
27
27
18
29
11
30
18