background image

Chapter 

8

Addendum Operating Instructions

 

S3000 PROFINET IO/IO OF 

34

 

© SICK AG • Industrial Safety Systems • Germany • All rights reserved 

8013291/YY95/2016-02-05 

Subject to change without notice 

Technical specifications 

8.3

 

PROFINET diagnostic messages 

Operating states:  

waiting for configuration 
lock-out 
device error 
error in the sensor head 
error in the I/O module 
error in the system plug 
measured value error in a 90° segment 
dazzle 
temperature error 
undefined monitoring case 
sequence error field set switching 
invalid input state 
contamination error or contamination measurement 
PROFIsafe communication error 

Содержание S3000 PROFINET IO Series

Страница 1: ...A D D E N D U M O P E R A T I N G I N S T R U C T I O N S S3000 PROFINET IO and S3000 PROFINET IO OF Safety laser scanner en...

Страница 2: ...his document is protected by the law of copyright whereby all rights established therein remain with the company SICK AG Reproduction of this document or parts of this document is only permissible wit...

Страница 3: ...nection 11 5 1 1 Voltage supply 12 5 1 2 Network connection with RJ845 push pull plug 13 5 1 3 Network connection with SCRJ push pull plug optical fiber 14 5 1 4 Local configuration connection 14 6 Co...

Страница 4: ...INET IO IO8OF Professional 31 8 2 1 INPUT 31 8 2 2 OUTPUT 32 8 3 PROFINET diagnostic messages 34 8 4 Response times 35 8 5 Data sheet 36 8 6 Services supported 37 8 7 Dimensional drawing S3000 PROFINE...

Страница 5: ...er with one of the following entries on the type label in the field Operating Instructions 8013289 8013289 TL59 8013289 US26 8013289 YAX9 8013289 YKY7 8013289 YY95 This document is part of SICK part n...

Страница 6: ...tection can be realised The safety level of the S3000 PROFINET IO IO8OF corresponds to category 3 PL d according to EN ISO 1384981 and SIL2 according to IEC 61508 2 2 General safety notes and protecti...

Страница 7: ...nto PROFINET IO networks supply connector with integrated configuration memory connection types S3000 PROFINET IO RJ845 sockets for RJ845 push pull plug S3000 PROFINET IO OF SCRJ sockets for VARIOSUB...

Страница 8: ...ts to an edge change on the reset signal from low to high not to the level The reset signal must be fail safe single failure proof 3 3 2 Control signals for switching monitoring cases You can switch b...

Страница 9: ...O IO8OF remains in the stand by mode as long as the related input information is present active high see Tab 10 on page 32 3 3 4 Initialising If the S3000 PROFINET IO IO8OF is in the lock out status e...

Страница 10: ...without notice Mounting 4 Mounting To calculate the safety distance and the size of the protective field when operated horizontally or vertically in stationary or mobile applications read the chapter...

Страница 11: ...nstallation 5 1 System connection The S3000 PROFINET IO IO8OF is installed electrically using the supply connector and using the two RJ845 ord SCRJ sockets System connection for RJ 45 System connectio...

Страница 12: ...Do not use 3 0 V DC Supply voltage Blue The external 24 V supply voltage may not exceed 40 V SELV or PELV This must be ensured during the electrical installation As an option a pre assembled supply c...

Страница 13: ...ith enclosure rating IP 65 e g Phoenix VS8PPC8C18RJ45 MNNA PG9 4Q5 material no 1608100 With the provided cover the connection complies with enclosure rating IP 54 If the network is not connected to a...

Страница 14: ...sage of optical adapter plugs the maximum allowed cable length to the next device is 50 m The maximum allowed line attenuation for the transmission link is 12 dB Pay attention to the mounting and wiri...

Страница 15: ...re words These words are separated using a The total length of the identifier is 1 to 240 characters The word length is 1 to 63 characters The identifier uses the following syntax Words comprise a z0...

Страница 16: ...PROFINET IO IO8OF to the hardware catalogue in the network engineering tool e g the SIMATIC Manager Siemens for PROFINET IO Insert the DVD CDS Configuration Diagnostic Software contained in the packag...

Страница 17: ...ne the IP address for the field device The IP address is defined in two steps 1 You use the device name assigned to the S3000 PROFINET IO IO8OF by the network engineering tool or you configure a uniqu...

Страница 18: ...change without notice Configuration 6 2 Configuration PROFIsafe In slots in the network engineering tool choose the command Object properties on the context menu On the PROFIsafe tab configure the pa...

Страница 19: ...omatically 1 to 65534 F_Dest_Add PROFIsafe destination address Must be unique in combination with the PROFIsafe source address and is assigned automatically Notes The PROFIsafe address for the S3000 P...

Страница 20: ...must have a PROFIsafe address The PROFIsafe address must correspond to the appropriate setting in the FPLC network engineering tool For this purpose in the network engineering tool in the PROFIBUS co...

Страница 21: ...rs e g wire break short circuit if the F peripheral has been rendered passive in the fail safe control If the S3000 PROFINET IO IO8OF is in the passive state it must be reintegrated Reintegration of t...

Страница 22: ...r 8009791 Using the CDS Configuration Diagnostic Software you can configure all available parameters and define the field geometries for the protective fields and warning fields The connection is made...

Страница 23: ...y laser scanner the LEDs have the following function LED illuminated PROFIsafe communication active no fault LED flashing at 0 5 Hertz Operator acknowledge requested by the FPLC LED illuminated Device...

Страница 24: ...rred If the display does not go out Check the configuration of the system using the CDS Configuration Diagnostic Soft ware Transfer the corrected configuration to the S3000 PROFINET IO IO8OF again Sen...

Страница 25: ...n no PROFIsafe active Check the configuration of the PROFINET IO see section 6 1 on page 15 and the confi guration of the safety laser scanner see operating instructions S3000 safety laser scanner SIC...

Страница 26: ...bility data in correct or front screen calibration failed Carry out a front screen calibration or re place the S3000 PROFINET IO IO8OF if necessary Internal error of the sensor head Replace the sensor...

Страница 27: ...d using the IO controller The help is saved in the GSDML 3 for the S3000 PROFINET IO IO8OF 7 3 1 I M function Identification Maintenance function The following data are loaded and displayed during the...

Страница 28: ...2 Simultaneous protective field unoccupied 0 3 Simultaneous warning field unoccupied 0 4 Reset required protective field 0 5 Reserved 0 6 Reset required simultaneous protective field Byte 0 0 7 Reserv...

Страница 29: ...erved 5 1 Reserved 5 2 Reserved 5 3 Reserved 5 4 Reserved 5 5 Reserved 5 6 Reserved Byte 5 5 7 Reserved 8 1 2 OUTPUT Bit Description 0 0 Monitoring case switching A1 0 1 Monitoring case switching A2 0...

Страница 30: ...erved 2 1 Reserved 2 2 Reserved 2 3 Reserved 2 4 Reserved 2 5 Reserved 2 6 Reserved Byte 2 2 7 Reserved 3 0 Reserved 3 1 Reserved 3 2 Reserved 3 3 Reserved 3 4 Reserved 3 5 Reserved 3 6 Reserved Byte...

Страница 31: ...unoccupied 0 3 Simultaneous warning field unoccupied 0 4 Reset required protective field 0 5 Reserved 0 6 Reset required simultaneous protective field Byte 0 0 7 Reserved 1 0 Contamination 1 1 Monitor...

Страница 32: ...d 5 4 Reserved 5 5 Reserved 5 6 Reserved Byte 5 5 7 Reserved 8 2 2 OUTPUT Bit Description 0 0 Monitoring case switching A1 0 1 Monitoring case switching A2 0 2 Monitoring case switching B1 0 3 Monitor...

Страница 33: ...erved 2 1 Reserved 2 2 Reserved 2 3 Reserved 2 4 Reserved 2 5 Reserved 2 6 Reserved Byte 2 2 7 Reserved 3 0 Reserved 3 1 Reserved 3 2 Reserved 3 3 Reserved 3 4 Reserved 3 5 Reserved 3 6 Reserved Byte...

Страница 34: ...fications 8 3 PROFINET diagnostic messages Operating states waiting for configuration lock out device error error in the sensor head error in the I O module error in the system plug measured value err...

Страница 35: ...response time of the control system and actuators Response time on protective field or warning field infringement S3000 basic response time resulting response time supplement due to multiple sampling...

Страница 36: ...eld sets Electrical data Electrical protection class III VDE 0106 EN 60950 Bus connection 2 standard PROFINET IO sockets for push pull plug connectors with metal housing RJ845 or SCRJ Supply connectio...

Страница 37: ...s reserved 37 Subject to change without notice Technical specifications 8 6 Services supported PROFINET IO with Conformance Class B LLDP according to IEEE 802 1 AB SNMP MIB II cyclic IO communication...

Страница 38: ...y All rights reserved 8013291 YY95 2016 02 05 Subject to change without notice Technical specifications 8 7 Dimensional drawing S3000 PROFINET IO IO OF Fig 16 Dimensional drawing S3000 PROFINET IO IO...

Страница 39: ...O Professional with medium range sensor head 5 5 m 1045653 S30A 7111CP S3000 PROFINET IO Advanced with long range sensor head 7 m 1045654 S30A 7111DP S3000 PROFINET IO Professional with long range sen...

Страница 40: ...57800 S30A xxxxDL I O module S3000 PROFINET IO8OF Professional 2057801 S30A 411 Sensor head 4 m 2049566 S30A 611 Sensor head 5 5 m 2049567 S30A 711 Sensor head 7 m 2049568 Sx1A A0000L Supply connector...

Страница 41: ...liance with EU directives EU declaration of conformity excerpt The undersigned representing the following manufacturer herewith declares that the product is in conformity with the provisions of the fo...

Страница 42: ...OFINET IO IO8OF Professional OUTPUT 32 Tab 11 Data sheet S3000 PROFINET IO IO8OF 36 Tab 12 Part numbers S3000 PROFINET IO with RJ 45 sockets 39 Tab 13 Part numbers S3000 PROFINET IO8OF with SCRL socke...

Страница 43: ...Addendum Operating Instructions Chapter 10 S3000 PROFINET IO IO OF 8013291 YY95 2016 02 05 SICK AG Industrial Safety Systems Germany All rights reserved 43 Subject to change without notice Annex...

Страница 44: ...one 81 0 3 5309 2112 E Mail support sick jp Malaysia Phone 603 808070425 E Mail enquiry my sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278...

Отзывы: