Table 28: File access control standard SFNC selectors
Selector
Type
Description
Visibility
FileSelector
enum
Selects the target file in the device.
Values:
Testfile, Update, CurrentLog, AllCrashLogs,
FirmwareUpdateLog
Guru
FileOperationSelector
enum
Selects the target operation for the selected file in the
device.
Values:
Open, Close, Write, Read, Delete
Guru
Table 29: File access control standard SFNC parameters
Parameter
Type
Description
Visibility
Access
FileAccessOffset[FileSelector]
[FileOperationSelector]
int
Controls the Offset of the mapping between the device
file storage and the FileAccessBuffer.
Guru
RW
FileAccessLength[FileSelector]
[FileOperationSelector]
int
Controls the Length of the mapping between the device
file storage and the FileAccessBuffer.
Guru
RW
FileOperationStatus[FileSelector]
[FileOperationSelector]
enum
File operation execution status.
Values:
Success
Failure
Guru
R
FileOperationResult[FileSelector]
[FileOperationSelector]
int
File operation result.
For Read or Write operations, the number of success‐
fully read/written bytes is returned.
Guru
R
FileOpenMode[FileSelector]
enum
Selects the access mode in which a file is opened in
the device.
Values:
Read
Write
ReadWrite
Guru
RW
FileSize[FileSelector]
int
The size of the selected file, in bytes.
Guru
RW
Table 30: File access control standard SFNC commands
Command
Description
Visibility
Access
FileOperationExecute[FileSelector][FileOpera‐
tionSelector]
Executes the operation selected by FileOperationSelec‐
tor on the selected file.
Guru
RW
7.13.10
Chunk data control
Table 31: Chunk data control standard SFNC parameter
Parameter
Type
Description
Visibility
Access
ChunkModeActive
bool
Activates the inclusion of Chunk data in the payload of
the image.
Beginner
RW
7.13.11
Test control
Normally, the user must not edit this feature. It is only intended for standard compli‐
ance testing.
Table 32: Test control standard SFNC command
Command
Description
Visibility
Access
TestEventGenerate
Generates a Test Event.
Used for GenICam standard compliance event testing.
Guru
RW
CONFIGURATION
7
8020774/14IM/2019-07 | SICK
O P E R A T I N G I N S T R U C T I O N S | Ranger3
43