Num‐

ber

Function

Parameter

Comment

3rd Sense

4th Sense

Max Sense

Adjusted

Configure via

Translucent

Teach

 

see OL1

“Teach mode” teach-

in menu, page 3

2

Measure polarity

Positive

see “Measure polar‐

ity” direction func‐

tion, page 3

Negative

3

Moving averaging

1

 to 

128

4

Zeroing value

-5.000

 Up to 

9.999

(

0.000

)

5

Measure Type

Edge

Width

6

Measure direction

Top

Object comes into

light band from above

Bottom

Object comes into

light band from below

7

Direction Checking

OFF

see Alignment of

sender - receiver

(“direction check‐

ing”), page 2

ON

8

Reset Settings

Not Reset

Execute by

 

A

“Measure polarity” direction function

Direction function only works with edge measurement (

Edge

).

1

OL1 sender

2

OL1 receiver

3

Upper

4

Lower

Use the direction function to configure how the measured values are displayed

from the top or bottom (cable side).
Positive: Top -5.000 mm, 5.000 mm
Negative: Top +5.000 mm, bottom -5.000 mm

6.2 OL1 “Teach mode” teach-in menu

Teach-in option

Number

Function

Comment

1

Zeroing

2

Reset Zeroing

3

Translucent Teach

Adapts the sensitivity value.

Translucent Teach

 is recommended

for semi-transparent materials to improve the

detection results

It is only possible to use the 

Translu-

cent Teach

 if the sensitivity is set to

Adjusted

 in the Setup mode

see OL1

“Setup mode” configuration menu, page 2

.

The 

Transluent Teach

 is run without

an object in the measuring range.

7

Application examples

1.

Keep pressing 

 until an arrow appears in front of 

Head 1 or 2

(depending on where the OL1 is assembled).

2.

To access the 

Top Menu

, press 

A

.

3.

To select 

Setup mode

, press 

.

4.

Press 

 until 

Measure Type

 is displayed.

5.

To select 

Edge

 or 

Width

, press 

 or 

.

6.

To confirm, press 

A

.

7.

To return to the main screen, hold 

B

.

8.

To exit the 

AOD1, Head 1, Head 2

 selection mode on the main screen,

press 

B

.

“Edge” detection application

Measure the edge position relating to the measuring range center of the light

band with leading edge detection 

see AOD1 device display and OL1, page 2

.

When more than one edge is in the measuring range, the device cannot

measure and show the value 

9.999

 (background remains black).

“Edge” detection application for transparent objects

NOTE

Safe edge detection is not guaranteed for very transparent objects (above

approx. 80% transmission).

The function works the same as for edge detection of non-transparent

objects.

The “Adjusted” value must be set in the “Sensitivity” setting for edge detec‐

tion of transparent objects. For optimal sensitivity adjustment, there must be

no measuring object between the sender and the receiver 

see OL1 “Setup

mode” configuration menu, page 2

 .

The direction from which the object protrudes into the measuring range must

be specified in the "Measure polarity" menu item 

see “Measure polarity”

direction function, page 3

.

“Width” and diameter measurement application

Measures the distance between two edges.

In this measurement type, the device shows the measured value of

0.000 mm to 9.999 mm.

The device distinguishes between light-dark and dark-light edges. Then the

width function can measure both the width and the gap.

In “Width” mode, there must always be exactly two edges inside the measur‐

ing range. If there are more than two edges inside the measuring range, the

output measured values are not specified.

If there is no or only one edge in the measuring range, the device shows an

alarm or “cannot be measured”.

The direction function (

Measure polarity

) does not work for width mea‐

surement.

Figure 1: Measurement of the gap between two objects edges

Figure 2: Measurement of object width

8

Cleaning

NOTICE

Equipment damage due to improper cleaning.

Improper cleaning may result in equipment damage.

Only use recommended cleaning agents and tools.

Never use sharp objects for cleaning.

Clean the front screen at regular intervals and in the event of contamination

using a lint-free lens cloth (part no. 4003353) and plastic cleaning agent

(part no. 5600006). The cleaning interval essentially depends on the ambi‐

ent conditions.

9

Technical data

NOTE

The relevant online data sheet for your product, including technical data,

dimensional drawing, and connection diagrams can be downloaded, saved,

and printed from the Internet:

www.sick.com/OL1

Please note: This documentation may contain further technical data.

9.1 Mechanics/electronics

Supply voltage V

S

12 V DC ... 24 V DC, ± 10%, including residual ripple

8022330/17Y7/2020-07-10/en