3.1 Scope of delivery
•
OL1 in the version ordered
•
Y-cable for connecting the OL1 sender and OL1 receiver
•
Printed operating instructions (this document)
•
Printed Safety Notes, multilingual (brief information and general safety
notes)
3.2 Mounting
1.
Ensure that the device is not connected to a voltage supply.
2.
Mount the AOD1 on the mounting rail.
3.
Mount the OL1 over the fixing holes.
4.
Align sensor heads in relation to the reference surfaces so that both top
sides and both side surfaces lie in the same plane.
1
1
2
3
3
3
3
3
2
1
Sender
2
Receiver
3
Reference surface
3.3 Alignment of sender - receiver (“direction checking”)
The receiver has two alignment LEDs to correctly assembly and align the sensor
heads. To use the alignment LEDs, activate the
Direction Checking
function
in the AOD1 menu.
1.
Keep pressing
until an arrow appears in front of
Head 1 or 2
(depending on where the OL1 is connected).
2.
To access the
Top Menu
, press
A
.
3.
To select
Setup mode
, press
.
4.
To display
Direction Checking
, press
.
5.
To select
ON
, press
.
6.
Complete with
A
.
✓
ON
is bracketed.
✓
The alignment LEDs are flashing.
7.
Align sensor heads so that both LEDs light up, but do not flash.
°
If no LED lights up on the receiver: Align sensor heads to one another.
°
When the red LED flashes: Move receiver upwards until both LEDs light
up.
°
When the green LED flashes: Move receiver downwards until both LEDs
light up.
1
OL1 sender
2
OL1 receiver
3
Upper
4
Lower
8.
After alignment, quit
Direction Checking
: Click on
, select
Off
and
confirm with
A
.
9.
To return to the main screen, hold
B
.
4
Electrical installation
1.
Connect OL1 sensor heads without voltage to the AOD1 with the supplied Y-
cable.
1
2
3
4
1
OL1 sender (connected with gray cable)
2
OL1 receiver (connected with black cable)
3
Y-cable
4
AOD1 (not included with delivery)
2.
Connect AOD1 to the voltage supply (see AOD1 Quickstart).
2
4
1
3
Y-cable connection diagram to AOD1, M8, 4-pin
Pin
Description
Color
1
Vcc
Brown
2
B (RS-485)
White
3
0 V
Blue
4
A (RS-485)
Black
5
Device description
Dimensions
Dimensions:
OL1E status LEDs (receiver)
Name
Color
Description
Power
Green
•
Lights up: Supply voltage on
•
Flashing: Device is in Direction checking
mode (
Direction checking
)
Alarm
Red
•
Lights up: Device displaying an alarm
•
Flashing: Device is in Direction checking
mode (
Direction checking
)
AOD1 device display and OL1
NOTE
See AOD1 Quickstart (no. 8019684) for an exact description of the operating
elements and menu structure of the AOD1.
AOD1 advertisement Schematic image
Description
9.999 background
changes to white
There is no object in the measuring range.
9.999 background
remains black
The object is larger than the measuring range.
-xxx
The object protrudes
into the measuring
range from above.
Measure
polarity
Set in a
positive direction
+xxx
Measure
polarity
Set in a
negative direction
+xxx
The object protrudes
from below into the
measuring range.
Measure
polarity
Set in a
positive direction
-xxx
Measure
polarity
Set in a
negative direction
6
OL1 menu
1.
Keep pressing
until an arrow appears in front of
Head 1 or 2
(depending on where the OL1 is connected).
2.
To access the
Top menu
, press
A
.
Top menu
Num‐
ber
Function
Parameter
Comment
1
Top Menu
Teach mode
–
Setup mode
–
Back
Return to basic
screen
6.1 OL1 “Setup mode” configuration menu
1.
To access the configuration menu, at the
Top Menu
press
.
Adjustment options
Num‐
ber
Function
Parameter
Comment
1
Sensitivity
Mini Sense
–
2nd Sense
–
8022330/17Y7/2020-07-10/en
OL1 | SICK
2