3.1 Scope of delivery

OL1 in the version ordered

Y-cable for connecting the OL1 sender and OL1 receiver

Printed operating instructions (this document)

Printed Safety Notes, multilingual (brief information and general safety

notes)

3.2 Mounting

1.

Ensure that the device is not connected to a voltage supply.

2.

Mount the AOD1 on the mounting rail.

3.

Mount the OL1 over the fixing holes.

4.

Align sensor heads in relation to the reference surfaces so that both top

sides and both side surfaces lie in the same plane.

1

1

2

3

3

3

3

3

2

1

Sender

2

Receiver

3

Reference surface

3.3 Alignment of sender - receiver (“direction checking”)

The receiver has two alignment LEDs to correctly assembly and align the sensor

heads. To use the alignment LEDs, activate the 

Direction Checking

 function

in the AOD1 menu.
1.

Keep pressing 

 until an arrow appears in front of 

Head 1 or 2

(depending on where the OL1 is connected).

2.

To access the 

Top Menu

, press 

A

.

3.

To select 

Setup mode

, press 

.

4.

To display 

Direction Checking

, press 

.

5.

To select 

ON

, press 

.

6.

Complete with 

A

.

ON

 is bracketed.

The alignment LEDs are flashing.

7.

Align sensor heads so that both LEDs light up, but do not flash.

°

If no LED lights up on the receiver: Align sensor heads to one another.

°

When the red LED flashes: Move receiver upwards until both LEDs light

up.

°

When the green LED flashes: Move receiver downwards until both LEDs

light up.

1

OL1 sender

2

OL1 receiver

3

Upper

4

Lower

8.

After alignment, quit 

Direction Checking

: Click on 

, select 

Off

 and

confirm with 

A

.

9.

To return to the main screen, hold 

B

.

4

Electrical installation

1.

Connect OL1 sensor heads without voltage to the AOD1 with the supplied Y-

cable.

1

2

3

4

1

OL1 sender (connected with gray cable)

2

OL1 receiver (connected with black cable)

3

Y-cable

4

AOD1 (not included with delivery)

2.

Connect AOD1 to the voltage supply (see AOD1 Quickstart).

2

4

1

3

Y-cable connection diagram to AOD1, M8, 4-pin

Pin

Description

Color

1

Vcc

Brown

2

B (RS-485)

White

3

0 V

Blue

4

A (RS-485)

Black

5

Device description

Dimensions

Dimensions: 

A

OL1E status LEDs (receiver)

Name

Color

Description

Power

Green

Lights up: Supply voltage on

Flashing: Device is in Direction checking

mode (

Direction checking

)

Alarm

Red

Lights up: Device displaying an alarm

Flashing: Device is in Direction checking

mode (

Direction checking

)

AOD1 device display and OL1

NOTE

See AOD1 Quickstart (no. 8019684) for an exact description of the operating

elements and menu structure of the AOD1.

AOD1 advertisement Schematic image

Description

9.999 background

changes to white

There is no object in the measuring range.

9.999 background

remains black

The object is larger than the measuring range.

-xxx

The object protrudes

into the measuring

range from above.

Measure

polarity

 Set in a

positive direction

+xxx

Measure

polarity

 Set in a

negative direction

+xxx

The object protrudes

from below into the

measuring range.

Measure

polarity

 Set in a

positive direction

-xxx

Measure

polarity

 Set in a

negative direction

6

OL1 menu

1.

Keep pressing 

 until an arrow appears in front of 

Head 1 or 2

(depending on where the OL1 is connected).

2.

To access the 

Top menu

, press 

A

.

Top menu

Num‐

ber

Function

Parameter

Comment

1

Top Menu

Teach mode

Setup mode

Back

Return to basic

screen

6.1 OL1 “Setup mode” configuration menu

1.

To access the configuration menu, at the 

Top Menu

 press 

.

Adjustment options

Num‐

ber

Function

Parameter

Comment

1

Sensitivity

Mini Sense

2nd Sense

8022330/17Y7/2020-07-10/en