8
Device
Table 3: Situation examples
Situation
Consequence
Trigger 3 is set while trigger 2 triggers the
exposure.
After trigger 2 is processed, trigger 3 is stored
and executed.
Trigger 5 is already stored, while trigger 6 is
triggered.
Trigger 6 is recorded. The results of trigger 5
and 6 are output in the correct order (PLC =
programmable logic controller).
3.8
Data transmission
During operation, the device continuously sends data packets via the data interfaces.
Interfaces for data transmission
•
Ethernet interface
•
RS422/RS232 (interface A)
•
Analog output (interface B, OD7000 Prime only)
The communication between the device and the computer is done using the dollar
protocol or the binary packet protocol. The device supports up to two network connec‐
tions simultaneously. Each network connection supports the dollar protocol or the
packet protocol. The supported protocol can be defined by the port through which the
connection is opened.
Table 4: Properties of the protocols
Dollar protocol
Packet protocol
•
Available via Ethernet TCP/IP (port 7890)
•
Economical measured value transmission
(2 bytes per measured value plus 2 byte
telegram header)
•
Human-readable command format that
allows setup and parameterization with a
simple terminal program.
•
Optional ASCII output of measured values
so that data output is readable for humans
with a simple terminal program.
•
Real-time data output (via serial interface)
•
In ASCII format or binary format
•
Available via Ethernet TCP/IP (port 7891)
•
Multi-client (2 clients per device)
•
Simple packet structure with reasonable
packet overhead
•
Data packets, data format packets, com‐
mand packets
•
Easily decodable
•
Easily expandable
3.9
Communication with the device
3.9.1
OD7000 Engineering Tool configuration software
OD7000 Engineering Tool
With the OD7000 Engineering Tool configuration software, you can, for example, config‐
ure the device, visualize measurements and save data via the Ethernet interface.
Further topics
•
Starting the configuration software
3.9.2
DLL
The DLL can be used to connect the device to a user program. Sensor configuration,
processing and transmission can be performed via the DLL. The DLL is written in C/C+
+ language and is intended for .NET compatible language.
PRODUCT DESCRIPTION
3
8027188//2022-05-25 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD7000
19
Subject to change without notice