Table 14: Adjustments for the upper and lower limit
Lower limit
Upper limit
25
μ
s (default value)
25
μ
s
50
μ
s
50
μ
s
100
μ
s
100
μ
s
200
μ
s
200
μ
s
500
μ
s
500
μ
s (default value)
1,000
μ
s
1,000
μ
s
7.3.5.5
Determining the direction of detection
The direction of detection determines whether the measured value increases (posi‐
tive) or decreases (negative) when the distance between the device and measuring
object increases.
1
2
3
4
5
0 mm
0 mm
Figure 39: Direction of detection
1
Set to positive
2
Set to negative
3
Sensor head
4
Center point of the measurement
5
Measuring object
To determine the order of the peaks,
see "Checking the light distribution curve and
7.3.5.6
Checking the light distribution curve and peaks
In this settings display, the user can check the light waveform which is displayed on the
receiver. The peak displays the distance to the measuring object. If the device detects
peaks then these are displayed in the corresponding light waveform and labeled P1 to
P8.