![SICK MLP1 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/sick/mlp1/mlp1_operating-instructions-manual_1264697036.webp)
Dimensions (W x H x D)
Actuator housing
Fiber-glass-reinforced PVC
Anchor plate
Nickle-plated steel
Weight
Safety switch
510 g
Actuator
210 g
Table 18: Inputs
Inputs
Rated voltage
24 V DC
Switching current
ON state
≤ 5 mA
OFF state
0 mA
Switching voltage
ON state
19.2 V DC ... 28.8 V DC
OFF state
0 V DC ... 2 V DC
Table 19: Outputs
Outputs
2 OSSDs (Out 1 and Out 2)
2 x PNP, max. 100 mA, short-circuit protected
and overload-proof
1 Application diagnostic output (Aux)
25 mA max,
1)
short-circuit protected (resistive
load)
Switching voltage (all outputs)
ON state
19.2 V DC ... 28.8 V DC
OFF state
0 V DC ... 2 V DC
Switching current (OSSDs)
ON state
≤ 100 mA
OFF state
≤ 500 µA
Test pulse duration (OSSDs)
300 µs
1)
A higher load affects the behavior of the status indicators,
see "Status indicators", page 11
Table 20: Ambient data
Ambient data
Enclosure rating
IP 67 (IEC 60529)
Ambient operating temperature
–20 °C … +55 °C
Storage temperature
-25 °C ... +70 °C
Relative humidity
50% at 70 °C (IEC 60947-5-2)
Vibration resistance
1 mm / 10 Hz ... 55 Hz (IEC 60068-2-6)
Shock resistance
30 g, 11 ms (IEC 60068-2-27)
EMC
In accordance with IEC 61326-3-1, IEC
60947-5-2, IEC 60947-5-3, and EN 300330
V2.1.1
Minimum distance between 2 safety switches
Depending on alignment,
eral safety switches", page 20