![SICK MLP1 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/sick/mlp1/mlp1_operating-instructions-manual_1264697026.webp)
Connecting safety switches connected with T-connectors
3
3
7
7
7
4
2
6
6
6
1
5
5
5
1
Safe evaluation unit
2
Connecting cable, M12, 5-pin
3
Connection cable, M12, 5-pin
4
End connector
5
MLP1 safety switch (M12, 8-pin)
6
T-connector
7
Connection cable, M12, 8-pin
DANGER
Bypassing the protective device
The dangerous state may not be stopped in the event of non-compliance.
If the cascade is created using T-pieces, install the connecting cables in a way that pre‐
vents a single T-piece (and therefore a safety switch) from simply being jumpered.
6
ELECTRICAL INSTALLATION
26
O P E R A T I N G I N S T R U C T I O N S | MLP1
8020169/ZJN1/2018-03-21 | SICK
Subject to change without notice