Working range diagram
Scanning range in m
Scanning range in m
–20
–40
20
40
60
–60
0
Scanning range max. 64 m
Scanning range for objects up to 10 % Remission 16 m
–40
40
–80
60
–20
20
0
Scanning range for objects up to 90 % remission 30 m
80
–60
275°
80
–80
Figure 38: Working area diagram, top view
10.2
Mechanics/electronics
Connection type
3 x M12 round connectors with swivel connector
Supply voltage
10 V DC ... 30 V DC
Permissible residual ripple
±5%
Power consumption
P
typ
= 18 W
P
start
= 35 W for 5 s (motor start-up)
P
max
= 42 W (with full specified current at all outputs)
Housing
ALSi12
Optics cover: PC
Housing color
Gray (RAL 7042)
Enclosure rating
IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)
IP67 (IEC 60529:1989+AMD1:1999+AMD2:2013)
Protection class
III (IEC 61140:2016-11)
Electrical safety
IEC 61010-1:2010-06
Weight
1.2 kg
Dimensions (L x W x H)
151.9 mm x 150 mm x 92.5 mm
Encoder input frequency
not available
Maximum output current
max. 100 mA per output
1)
e.g., 30 V*100 mA = 3 W
10
TECHNICAL DATA
48
O P E R A T I N G I N S T R U C T I O N S | LMS1104C-111031S01
8023051/1AZG/2021-05-10 | SICK
Subject to change without notice