![SICK Lector63x Flex C-mount Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/sick/lector63x-flex-c-mount/lector63x-flex-c-mount_operating-instructions-manual_1264271049.webp)
Function assignment
NOTE
Assign the functions for the digital inputs in the device using a configuration tool, e.g.,
the configuration software SOPAS ET.
External digital outputs
If the CMC600 cloning module is used in the CDB or CDM connection module, 2
additional external digital outputs (external output 1, external output 2) are available.
The external digital outputs are located at the terminals of the connection module.
For the electrical characteristic data of the external digital outputs, see the connection
diagrams for the connection modules in these operating instructions.
NOTE
The external digital inputs are software-controlled and therefore do not offer the same
timing precision as physical digital inputs. The external digital inputs may not be suita‐
ble for time-critical applications.
Wiring digital outputs via connection module
Connection mod‐
ules
Digital outputs
Reference
CDB650-204
RES/OUT 1
RES/OUT 2
RES/OUT 3
RES/OUT 4
see "Wiring digital outputs of
the device in the CDB650-204",
page 80
External output 1 (EXT. OUT 1)
External output 2 (EXT. OUT 2)
see "Wiring the external digital
outputs of the device in the
CDB650-204", page 81
CDM420-0006
Result 1
Result 2
see "Wiring digital outputs of
the device in the CDM420-0006",
page 93
External output 1 (AUX Out 1)
External output 2 (AUX Out 2)
see "Wiring the external digital
outputs of the device in the
CDM420-0006", page 94
ELECTRICAL INSTALLATION
6
8018071/1E1C/2021-12-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
49
Subject to change without notice