168
FC1-Value within Code
parameter can be used to define an alternative character
for the separator (control character within the code) in the case of the EAN 128 code
format.
Up to three characters can be defined. The values must be entered as decimal num‐
bers.
169
Errors in L-pattern
According to the ISO/IEC 16022 standard, the code structure (L pattern) is not allowed
to have any gaps in it and must extend across the entire code height and width. If the
parameter is activated, codes can still be read even if they contain
defective code structures.
This means that any gaps in the code structure are ignored during decoding. So that
the code can still be read, there must be a quiet zone around the code that is at least
five times as big as the cell size. This may increase the decoding time.
170
Error Score 1
parameter is used to define a value that serves as the
definition of a correctly read character. This specified value must be achieved for the
character to be detected. If the value is not achieved, a “?” is output in the output for‐
mat for this character.
The parameter can also be used as a quality mark to detect poorly printed characters/
text, for example. The
parameter can also be used to gen‐
erate an event, e.g., an output signal.
171
Fieldbus Gateway
All settings for connecting the reading device to a gateway are made on the
tab. The gateway can be configured directly via the reading device. The gate‐
way and reading device communicate via the serial interface.
The reading device is incorporated into the required fieldbus via a gateway.
172
Fixed size 1
A fixed symbol size can be selected using the
parameter. Only codes with
this symbol size are read.
By defining the specific symbol sizes that are permissible, you can restrict the range of
codes to be read. This can lead to a reduction in the decoding time.
173
Fixed size 2
A fixed symbol size can be selected using the
parameter. Only codes with
this symbol size are read.
By defining the specific symbol sizes that are permissible, you can restrict the range of
codes to be read. This can lead to a reduction in the decoding time.