375
Tx Header
parameter is used to define a header for the received data, which is
applied when the data is output. Once the data has been received, the
and
are removed. The string is reframed with the
and
so that it can be output.
The input is restricted to two characters and must be entered via the context menu or
the
button. It is possible to enter control characters and constants. The input
field is highlighted in red if invalid characters are entered.
376
Tx Terminator
parameter is used to define a terminator for the received data, which
is applied when the data is output. Once the data has been received, the
are removed. The string is reframed with the
so that it can be output.
The input is restricted to two characters and must be entered via the context menu or
the
button. It is possible to enter control characters and constants. The input
field is highlighted in red if invalid characters are entered.
377
Monitored Devices
parameter is used to specify the device IDs of the nodes that
are to be monitored by the reading device. The device IDs are separated by commas.
NOTE
The input field is highlighted in red if an invalid entry is made.
Max. startup time for the monitored devices
Max. startup time for the monitored devices
parameter defines an interval in sec‐
onds for the startup time of the monitored devices. A node is considered available if the
time gaps between the sent signals are within the specified interval.
378
Monitoring
The CAN network monitoring function is activated and configured in the
group.
assign to
parameter is used to activate or deactivate the CAN network monitoring
function for the reading device.
•
DEACTIVATED
: The device does not monitor any other reading devices.
•
CAN
: The reading device monitors other reading devices on the CAN bus. The
device responsible for monitoring detects which nodes are available and which
devices have dropped out.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK
O N L I N E H E L P | Lector62x
123