background image

8018061/2015-04-13

• Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com

2

Lector

®

632 | SIcK

Image handling controls

The image handling controls are used to change how 

images are viewed.

Button

Function

Description

Select

Click and drag to change region 

size and position.

Move

Click and drag to move the image.

Zoom

Click and drag upwards to zoom in 

and downwards to zoom out.

Home

Click to fit image area to view.

Filmstrip

The expandable filmstrip area shows the image his

-

tory as thumbnails. When the image acquisition is 

stopped it is possible to click a thumbnail to see it 

enlarged.

information area

The expandable information area contains the 

D

evice

 

infO

, l

Ogs

 and 

s

ystem

 

status

 tabs.

The 

D

evice

 

infO

 tab displays device-related information 

such as IP address and serial number.
The 

l

Ogs

 tab contains controls to retrieve logged 

images.
The 

s

ystem

 

status

 tab shows system warnings and 

errors.

Workflow

Follow the workflow in the parameter panel to config

-

ure the Lector63x. While the steps are arranged in the 

typical configuration order, it is possible to navigate 

freely between the steps. 

1. Image

The 

i

mage

 workflow step controls how and when im

-

ages are acquired.
The 

l

ens

 & f

Ocus

 

section controls lens type selection 

and displays focus feedback.
The 

b

rightness

 section controls the visual quality of 

acquired images. Use the 

a

utO

 

gain

 

button to automati-

cally adjust the gain.
The 

i

lluminatiOn

 section controls the internal and exter-

nal lighting behavior. The internal lighting is enabled 

by default.

NOTICE

For Lector632x Flex, the focusing of the image is 

done mechanically on the device (S-mount) or on 

the lens (C-mount). To protect the device (S-mount) 

from focus manipulation attach the supplied round 

label to the hole in the device lid.

The 

triggering

 section controls the acquisition mode 

and triggering method:

acquisition 

mode

Description

Single image

• 

Acquires one image and outputs one 

result per trigger signal. 

• 

Used when there is only one acquisition 

and analysis per object.

• 

Used when the code is precisely 

positioned on the object in high speed 

applications.

Image series

• 

Acquires a series of images and typically 

outputs one combined result per trigger 

signal. 

• 

Used when the object is larger than the 

field of view and the exact code position 

is unknown. 

• 

Used to increase read rate by acquiring 

each code multiple times.

Image series is enabled by default.

2. task

The 

t

ask

 workflow step contains the code reading 

parameters. 
The 

c

ODe

 

reaDer

 

settings

 section determines which 

code types to read. Advanced settings are available 

for performance optimization.
The 

c

ODe

 

reaDer

 

results

 section contains unformatted 

results for the current image, such as the read result 

and code print quality.
The results are presented in a table where each row 

represents one code.

3. results

The 

r

esults

 workflow step contains settings for result 

timing, post-processing and formatting.
The 

O

utPut

 

cOntrOl

 

section determines when the result 

shall be output, either:

• 

Directly when processing is ready

•  At a fixed response time

The 

c

Ounters

 

section contains counters which for 

example can be used to set conditional outputs.

The 

c

OnDitiOns

 

section allows creation of custom condi-

tions for device control and result logic. The 

g

OOD

r

eaD

 

condition is pre-defined as an example:

The 

D

igital

 

OutPuts

 section specifies which results are 

published on the available outputs.
In the 

O

utPut

 

fOrmat

 section, the decoding result 

can be formatted to a string in a visual editor. The 

example below shows how the GoodRead condition is 

used to output the content of all read codes.

The 

b

eePer

, f

unctiOn

 leD 

and 

f

eeDback

 

sPOtlight

 sec-

tions contain settings to define custom outputs for 

monitoring results without a screen.

4. interfaces

The 

i

nterfaces

 workflow step contains settings for con

-

nections to external interfaces.
The 

i/O 

DefinitiOns

 section defines the physical behav

-

ior of the digital inputs and outputs.
The 

e

thernet

 section sets up Ethernet communica-

tions with peripheral equipment.
The 

s

erial

 section sets up serial communications with 

peripheral equipment.
The 

l

Ogging

 section controls logging of data from the 

device to internal and external destinations: Device 

RAM, MicroSD card and external FTP server.
The 

e

ncODer

 section sets up one of the digital inputs 

to receive encoder signals. For example, increment-

controlled acquisition and result output make the 

system independent of conveyor speed.
The 

m

aster

/s

lave

 section sets up camera-to-camera 

communication in a SICK CAN network.
The 

f

unctiOn

 

buttOns

 

On

 

Device

 section defines the 

behavior of the device buttons.
The 

D

evice

 

time

 section specifies how to set the device 

time manually or to synchronize with an external time 

server.

License text

SICK uses open source software in its Lector63x sen-

sors. This software is licensed by the rights holders 

using the following licenses among others: the free 

licenses GNU General Public License (GLP Version2, 

GPL Version3) and GNU Lesser General Public 

License (LGPL), the MIT license, zLib license, and the 

licenses derived from the BSD license. 
This Program is distributed in the hope that it will be 

useful, but WITHOUT ANY WARRANTY; without even 

the implied warranty for merchantability or fitness 

for a particular purpose. See the GNU General Public 

License for more details. 
View the complete license texts here: www.sick.com/

licencetexts. A printed copy of the license texts is also 

available on request.

Содержание Lector 632

Страница 1: ...external I O signals to the Lector63x while it is powered Configure with PC The SOPAS Engineering Tool ET software for PC is used to connect and configure the Lector63x and other SICK devices To install SOPAS ET 1 Download SOPAS ET version 3 0 1 or newer from www mysick com en SOPAS_ET 2 Run the downloaded installation file 3 Follow the instructions on the screen SOPAS ET main window The SOPAS ET ...

Страница 2: ...der results section contains unformatted results for the current image such as the read result and code print quality The results are presented in a table where each row represents one code 3 Results The Results workflow step contains settings for result timing post processing and formatting The Output control section determines when the result shall be output either Directly when processing is re...

Страница 3: ...LR CCS FIeldbuses 1 External light ICL 2 Connection box 3 Fieldbuses 4 I O box 5 24 V DC power source 6 Encoder 7 Photoelectric switch 8 External light VLR CCS 9 PC ß External FTP server à HMI operator interface á PLC control system â Power cable for example no 2055419 2 m ã Ethernet cable for example no 6034414 2 m Power SerialData CAN IO USB no image transfer External light Gb Ethernet 11 5 13 7...

Страница 4: ...IN EAN 2D code types Data Matrix ECC200 GS1 Data Matrix MaxiCode QR code Stacked code types PDF417 Postal Code qualification On the basis of ISO IEC 16022 ISO IEC 15415 ISO IEC 15416 ISO IEC 18004 Interfaces Data store and retrieve Image and file logging via MicroSD memory card internal RAM and external FTP Switching inputs Max 6 internal 24V 4 configurable as in out additional 2 inputs via option...

Отзывы: