OUT
Deactivated (factory setting)
OUT
Active
7.
Press the Mode button.
NOTE
When using the “2-point” or “Dynamic” teach-in mode, the second teach-in point must
then be defined by pressing the mode pushbutton. When combining units with different
teach-in types, it might be necessary to also define the second teach-in point. In this
case, units with 1-point teach-in are not influenced.
7.6.9
Setting synchronization
The synchronization type is only available in bus operation. If synchronization is
switched off, fiber contrast sensors measure independently of each other at maximum
speed in bus operation. However, mutual interference can occur if the field of view of
the fibers overlaps.
If synchronization is switched on, fiber contrast sensors measure in sync one after
another to prevent mutual interference. This reduces the measurement speed.
1.
Press and hold the Mode button for 2 s.
2.
Use the plus or minus button to select Pro.
OUT
3.
Press the Mode button.
4.
Use the plus or minus button to select SYnC.
OUT
5.
Press the Mode button. The preset value flashes.
OUT
6.
Use the plus or minus button to select on or oFF.
OUT
Deactivated (factory setting)
OUT
Active
7.
Press the Mode button.
7.6.10
Setting continuous threshold adaptation
When continuous threshold adaptation is switched on, slow changes to the signal level
are monitored. When such changes occur, the threshold is changed appropriately. This
function can help to ensure reliable switching even in environments with increased con‐
tamination.
7
OPERATION
34
O P E R A T I N G I N S T R U C T I O N S | KTL180
8023304.11XV/2018-11-29 | SICK
Subject to change without notice