4
Device
5
Master
6
Device number
7
CAN etc.
8
Slave
9
Branch line
ß
An adapter cable (female connector, M12, 17-pin, A-coded / male connector, D-Sub-HD, 15-pin) is required to connect
the device
à
Device number (GN)
á
Maximum 32 users
â
Alternative connection module CDB650-204.
NOTE
Control the CAN data interface in the device with the API functions. In order to activate
the CAN data interface, use an installed SensorApp which contains this function.
13.4.6
Wiring digital inputs of the device in the CDM420-0006
Device = InspectorP61x = V2D61xP- xxxxxEx
Device
4
CDM420-0006
PNP sensor
8
V
S
V
S
V
S
GND
SensGND
52.3 K
3 K
Sensor
E
V
in
D
9
2
1
C
15
1
5
Out
+24V*
GND
S6
ON
OFF
S6 : SGND-GND
Shield
GND
.
.
.
A
Sensor
B
37 SGND
6 Shield
39 +24 V*
GND
SensGND
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
Trigger sensor
1
9
E.g. photo-electric
switch
7
3
6
5
1
10
15
6
11
5
Cable
2
Figure 42: Trigger sensor supplied with power by connection module CDM420-0006
1
Trigger sensor, e.g. for read cycle generation
2
Adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-coded)
3
Input voltage V
in
4
Device
5
Connecting cable permanently connected with the device (male connector, M12, 17-pin, A-coded)
6
Connection module: female connector, D-Sub-HD, 15-pin
7
e.g. photoelectric sensor
8
PNP sensor
9
Supply voltage V
S
ANNEX
13
8026257//2020-12 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP61x
71