COMMISSIONING AND CONFIGURATION
6
71
8011325/18IM/2020-07-02|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | ICR880/890
If the number ranges for the configuration PC and the camera system correspond, then
the camera systems are detected and displayed in the device list on the right-hand side.
The camera systems use two ports (like all SICK devices). Ports are part of the network
address and can be used to establish various connections between the devices. Port
2112
is freely configurable but port
2111
is a fixed port for outputting data. It is used for
device configuration.
6.2.5
Transferring the camera system to a SOPAS project
Add the detected camera systems to the SOPAS project.
1. In the list, select the camera system with the port
2111
.
2. Click the
Add
icon to transfer the device into the project.
Alternatively, you can transfer by double-clicking on the list entry or dragging and
dropping.
The transferred camera system is displayed in the left-hand window as a
tile
.
A notification will appear if the device drivers for the camera system are not yet known in
the SOPAS project.
Note
Note