7
Technical specifications
7.1
General system data
i17-SA213
i17-SA214
Housing material
Glass-reinforced polyester
Enclosure rating (IEC 60529)
IP67
IP65
Mechanical life
1 × 10
6
switching operations
B1
10D
(EN ISO 13849-1)
2 × 10
6
switching operations with low load
Type
Type 2 (EN ISO 14119)
Actuator coding level
Low coding level (EN ISO 14119)
Operating temperature
–20 … +80 °C
Type of connection
3 × M20
3 × M12
Approach speed max.
10 m/min
Retaining force max.
12 N
Actuation frequency max.
7200/h
Contact elements positively guided
NC contacts/NO contacts
2/1
Rated impulse withstand voltage
U
imp
contacts referred to housing
2500 V
1500 V
Rated insulation voltage U
i
250 V
25 V
Usage category (IEC 60947-5-1)
AC-15: 240 V/3 A
DC-13: 24 V/2 A
AC-15: 25 V/4 A
DC-13: 24 V/2 A
Switching voltage min.
5 V DC
Switching current min. at 5 V DC
5 mA
Connection cross-section
1,5 mm²
0,5 mm²
Short-circuit protection
T10/10 A
T4/4 A
Torque requirements for screws
Mounting screws housing
Cover screws
Jam screws contacts
1,4 Nm
1,2 Nm
1,0 Nm
Minimum door radius
7.2
Dimensional drawings
3,5
17,5
(0.57)
14,5
52 (2.05)
M5 C SK
31,2 (1.23)
5 (0.2)
40 (1.57)
(0.69)
(0.14)
Figure 8: Dimensional drawing actuator iE17-S1
TECHNICAL SPECIFICATIONS
7
8027215/1CY3/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | i17S
13
Subject to change without notice