![SICK i11s Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/sick/i11s/i11s_operating-instructions-manual_1264689013.webp)
7
Technical data
7.1
General system data
Housing material
Glass-fibre reinforced thermoplast
Enclosure rating in compliance with IEC 60529 IP67
Mechanical life
1 × 10
6
switching operations
B
10d
(EN ISO 13849) at DC-13 100 mA / 24 V
(positive opening normally closed contact)
4 × 10
6
switching operations
Type
Type 2 (EN ISO 14119)
Actuator coding level
Low coding level (EN ISO 14119)
Operating temp.
–20 ... +80 °C
Type of connection
3 × M16
Switching principle for switching elements
Slow-action switch
Switching elements of forced opening/closing
devices
2/1
Approaching speed max.
20 m/min
Frequency of use (maximum)
7000/h
Actuation power
10 N
Retaining force
10 N
Rated withstand voltage U
imp
2,5 kV
Contamination level
(external, acc. to EN 60947-1)
3 (industry)
Rated insulation voltage U
i
250 V
Usage category in compliance with EN
60947-5-1
AC-15: 230 V 4 A
DC-13: 24 V 4 A
Switching voltage min.
12 V DC
Switching current min. at 24 V DC
1 mA
Wire cross-section (rigid/flexible)
0,34 … 1,5 mm
2
Conventional thermal flow I
th
4 A
Conditional short circuit current
100 A
Short-circuit protection (control safety IEC
60269-1)
4 A gG
Breakaway torque for screws
Mounting screws housing
Cover screws
Jam screws contacts
Head screw
1,5 Nm
0,8 Nm
0,5 Nm
0,8 Nm
Minimum approach radius
TECHNICAL DATA
7
8027740/1FVF/2022-05-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | i11s
13