Avoid shiny surfaces in the measurement area since these cause beam deflections
and therefore faulty measurements due to false echoes. False echoes may be able to
be suppressed by selecting the suitable “Echo selection” parameter,
5.4
Mounting/Disassembling additional filter (DT1000 only)
Mounting additional filter
When using the additional filter, the sensing range of the DT1000 is reduced.
As long as there is no fog or steam in the light beam area, deactivating the fog filter set
at the factory is recommended.
1.
Set the additional filter on the upper front edge of the distance sensor so the
locking screws of the additional filter lie on the screw heads of the housing screws:
3
4
1
2
2.
Press the additional filter onto the front side of the distance sensor so the snap
hook of the additional filter enrages in the recess in the underside of the housing:
3.
Tighten locking screws to fasten the additional filter:
3
4
1
2
Disassembling additional filter
1.
Unscrew locking screws:
MOUNTING
5