8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 23
Operating instructions Distance measuring device DL100 Pro – RS-422
Mounting
6 Mounting
6.1
Mounting process
1. Determine mounting site under consideration of the mounting notes.
→
See following chapter.
2. Mount alignment bracket and distance measuring device.
→
3. Perform electrical connection.
→
4.
Align distance measuring device and reflector against each other.
→
5.
Align distance measuring device with the reflector using the alignment
bracket fine adjustment.
→
6. Fasten alignment of the distance measuring device.
→
6.2
Mounting notes
Observe the follwong mounting notes for trouble-free operation:
•
Comply with technical specifications like the measurement range.
→
• Use distance measuring device with optional heating in low ambient
temperatures, e.g. in deep freeze storage.
• At higher temperatures, use the distance measuring device with optional
cooling casing.
→
• Protect the distance measuring device from solar irradiation.
• To avoid condensation, do not expose the distance measuring device to
any quick temperature changes.
•
Observe the assembly notes for the reflector.
→
•
Keep sufficient distance to other distance measuring devices.
→
•
Keep sufficient distance to data transmission photoelectric switches.
→