Monitoring
The scanners which are to be monitored by this scanner can be set via the parameters of
the
group.
Multiplexer
The multiplexer network is configured via the parameters of the
group.
Each scanner in the CAN network can emulate the functions of the multiplexer. Therefore,
a cooperation of scanners can be established with just one interface to the host without the
need of an additional multiplexer device. A multiplexer can operate up to 31 slave scanners.
The multiplexer sends all reading results or data strings received by a slave scanner to the
host. The device number of the scanner is added to the reading result.Therefore, the host
can distinguish between the different data sources. Furthermore, the host has the possibil-
ity to send addressed data strings to the multiplexer which are then transferred to the cor-
responding scanner in the network.
2.2.5.1 Serial
Serial host interface
The serial host interface is configured with the parameters of the
group.
The serial host interface provides the reading result for further processing by the host com-
puter.
Parameter
Function
Assign to
Select connection for monitoring
Monitored devices
Enter the device numbers of the scanners which are to be moni-
tored by this scanner.
Maximum starting time of moni-
tored devices
Enter time during which a missing signal of a monitored device
will be ignored.
Parameter
Function
Assign to
Select connection for multiplexing.
Server list
Enter device numbers of scanners which participate in the multi-
plexing.
Parameter
Function
Protocol / Output format
Select the format for the output of the reading result via the serial
host interface.
Multiplexer output
Activate/deactivate data output via multiplexer.
Baudrate
Select speed of serial host interface.
Stopbits
Select number of stopbits.
Databits / Parity
Select number of databits and parity.
Hardware
Select the type of serial host interface.
Activate heartbeats
Activate the output of a regular heartbeat.
Heartbeat interval
Enter time between two heartbeats.
Restart interval on sending
Restart interval after the output of a reading result.
Gateway
Activate PROFIBUS DP interface or DeviceNet respectively.