Electrical installation
6.1
Overview of installation sequence
Important
Electrical installation must be performed by qualified staff.
The following list provides an overview of a typical installation sequence:
•
Connecting the bar code scanner to connection module CDB620 or CDM420
•
Wiring the bar code scanner's data and function interfaces
•
Connecting the connection module to the supply voltage
•
Connecting a PC for start-up and configuration (RS-232 or Ethernet)
The actual installation work which has to be carried out depends on the respective system
configuration and the version of the bar code scanner (see
chapter 6.2 Electrical installa-
). Once electrical installation has been completed, the bar code
scanner is started up and configured (see
chapter 7 Startup and configuration, page 57
6.2
Electrical installation preparation
The following general requirements should be observed for the electrical installation:
•
Supply voltage 10 ... 30 V DC (functional extra-low voltage in accordance with IEC 364-
4-41 (VDE 0100 Part 410)) and min. 5 W output power
– Using connection module CDB620/CDM420: supply voltage provided by terminals
of the connection module
- or -
– Free wiring by customer (without connection module CDB620/CDM420): connec-
tion of supply voltage e.g. by cable no. 6034418 (15-pole D-Sub-HD socket to open
end)
•
With external reading pulsing
– Appropriate reading pulse sensor (start/stop), e. g. photoelectric reflex switch:
for registering an object in the reading area
– Additional appropriate reading pulse sensor (stop), e.g. photoelectric reflex switch:
For registering the end of pulse with extended external reading pulse
•
Appropriate incremental encoder: For separating identical bar codes
•
Host computer with RS-232, RS-422/485 data interface or Ethernet: For further
processing the reading data
•
Connection cables: See
chapter 11.4.7 Accessories: Cables for Ethernet version,
Important
The possible distance between the bar code scanner and the host computer depends on
the physical version of the selected host interface and the set data transfer rate.
The following tools and resources are required for electrical installation:
•
Tool
•
Digital measuring device (current/voltage measurement)