Chapter
5
Operating Instructions
CLV 42x bar code scanner
5-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 981/O078/16-08-2004
Electrical connection
In the default setting, the CLV communicates with the host via the host interface using the
values shown in
.
For connecting the host interface via the CDB 420 or CDM 420 Connection Module, see the
“
CDB 420 Connection Module“ Operating Instructions (order no. 8 010 001, German/
English version)
respectively the
“CDM 420 Connection Module“ Operating Instructions
(order no. 8 010 004, German/English version).
Terminating the RS 422 interface
The interface can be terminated in the CDB 420 or CDM 420 connection module.
See
Operating Instructions for the "CDB 420 or CDM 420 connection module".
Activating the RS 232 interface
The RS 232 interface can be activated with the CLV Setup program:
1.
Choose the H
OST
I
NTERFACE
tab.
2.
Choose the "RS 232" option from the H
ARDWARE
drop-down list under D
ATA
F
ORMAT
.
3.
Perform a download to the CLV. This is done by clicking
in the toolbar.
The D
OWNLOAD
P
ARAMETER
dialog window is displayed.
4.
Confirm the dialog window by selecting the P
ERMANENT
save option.
The CLV uses the RS 232 version of the host interface.
TIP
The communication parameters can be changed, if necessary, on the H
OST
I
NTERFACE
tab.
To do so, change the values under D
ATA
F
ORMAT
and I
NTERFACE
P
ROTOCOL
.
5.5.5
Connecting the CAN interface
For information on the connection and parameterization of the CLV for use in a SICK scanner
network or in a CANopen network, see the Operating Instructions
"Application of the CAN
interface" (no. 8 009 180, English version).
Parameter
Value
Interface model
RS 422/485
Data transfer rate
9,600 bd
Data bits
8
Parity
none
Stop bits
1
Protocol
SICK (start character: STX, stop character: ETX, no request for
repeat: none, timeout: 50 ms)
Table 5-5: Communication parameters for the host interface (default setting)