![SICK C4-RD Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/sick/c4-rd/c4-rd_operating-instructions-manual_1264345064.webp)
Protective field
height in mm
Typical power consumption of
sender in W
Typical power consumption of
receiver in W
1)
Resolution
14 mm
Resolution
30 mm
Resolution
14 mm
Resolution
30 mm
500
1.12
0.88
2.24
1.76
550
1.16
0.90
2.32
1.79
600
1.20
0.91
2.40
1.82
750
1.32
0.96
2.64
1.92
900
1.44
1.01
2.88
2.02
1050
1.56
1.06
3.12
2.11
1200
1.68
1.10
3.36
2.21
1350
1.80
1.15
3.60
2.30
1500
1.92
1.20
3.84
2.40
1)
Power discharged again via the OSSDs depending on the connected OSSD load must be added to the
table values.
12.4
Length of cable
Table 17: Maximum lengths of cable for wire cross-section 0.34 mm
2
, copper wire
Single system
Separate connecting cables for
sender and receiver
r
s
b
c
S
r
s
b ≤ 85 m
c ≤ 15 m
Connection of sender and receiver
via T-connector on the sender
r
s
a
T
c
S
r
s
a + c ≤ 15 m
Connection of sender and receiver
via T-connector on the receiver
r
s
a
T
b
S
r
s
a ≤ 15 m
b ≤ 85 m
S
Control cabinet with safety relay or safety controller
T
T-connector
12.5
Table of weights
Table 18: Weight of sender and receiver
Protective field height in mm
Weight in g
1)
s
Sender
r
Receiver
150
145
147
200
189
191
250
234
236
300
278
280
12
TECHNICAL DATA
64
O P E R A T I N G I N S T R U C T I O N S | C4-RD
8025644/19Z2/2021-03-09 | SICK
Subject to change without notice