Minimum
Typical
Maximum
Housing cross-section
31 mm × 34 mm, plus bracket,
Vibration resistance
4)
5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance
5)
10 g, 16 ms (IEC 60068-2-27)
1)
Maximum permissible conductor resistance must be observed.
2)
The temperature difference between sender and receiver must not exceed 25 K.
3)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25
°C.
4)
Test conditions per axis: 1 octave/minute, amplitude: 0.35 mm, 20 sweeps.
5)
Test conditions per axis: 1,000 shocks.
12.2
Response time
Table 15: Response time dependent on the protective field height
Protective field height in mm
Response time in ms
Resolution 14 mm
Resolution 30 mm
150
10
9
200
10
9
250
10
9
300
11
10
350
11
10
400
11
10
450
12
10
500
12
10
550
12
10
600
13
10
750
13
11
900
14
11
1050
15
11
1200
16
12
1350
17
12
1500
18
13
12.3
Power consumption
Table 16: Power consumption, sender and receiver
Protective field
height in mm
Typical power consumption of
sender in W
Typical power consumption of
receiver in W
1)
Resolution
14 mm
Resolution
30 mm
Resolution
14 mm
Resolution
30 mm
150
0.84
0.77
1.68
1.54
200
0.88
0.78
1.76
1.57
250
0.92
0.80
1.84
1.60
300
0.96
0.82
1.92
1.63
350
1.00
0.83
2.00
1.66
400
1.04
0.85
2.08
1.70
450
1.08
0.86
2.16
1.73
TECHNICAL DATA
12
8025644/19Z2/2021-03-09 | SICK