Commissioning
>
Switch the power supply off and then back on again and check via the 7-segment display
whether the alignment is correct after tightening the clamping bolts table 11.
The display values have the following meaning:
Notes
·
If the optimum alignment (= no display) persists for longer than 2 minutes, the system
automatically deactivates the alignment mode.
·
If you wish to readjust the alignment later, switch the power supply of the C 4000 off and
back on again.
·
The host in a cascaded system remains on red until all guests have been accurately
aligned.
6.3
Test notes
6.3.1
Tests before the first commissioning
The purpose of the tests before the first commissioning is to confirm the safety require-
ments specified in the national/international rules and regulations, especially in the
Machine and Equipment Usage Directive (EU Conformity).
>
Check the effectiveness of the protective device mounted to the machine, using all
selectable operating modes as specified in the checklist in the annex (see 12.2 on
page 60).
>
Make sure that the operating personnel of the machine secured by the light curtain are
properly instructed by specialist personnel before being allowed to operate the machine.
Instructing the operating personnel is the responsibility of the machine operator.
>
Annex 12.2 of this document shows a checklist for review by the manufacturer and OEM.
Use this checklist as reference before commissioning the system for the first time.
6.3.2
Regular inspection of the protective device by qualified personnel
>
Check the system, following the inspection intervals specified in the national rules and
regulations. This procedure ensures that any changes on the machine or manipulations
of the protective device are detected before commissioning.
>
If substantial modifications have been made to the machine or the protective device, or
if the safety light curtain has been changed or repaired, the system must be checked
again as specified in the checklist in the annex.
Display
Meaning
0
The receiver cannot synchronise with the sender; the alignment is highly
inaccurate.
1
Some light beams do not hit the receiver.
2
All the light beams hit the receiver, but the alignment is still slightly off.
No display
or
r
The alignment is now true; the devices must be locked in this position.
Display
r
appears if the device is operated with reduced resolution
and/or with blanking.
Tab. 11: Display values during
the alignment of sender and
receiver