12.2 Checklist for the manufacturer
Checklist for the manufacturer/OEM for the installation of
electro-sensitive protective equipment (ESPE)
The details on the items listed below must be available at the latest when the system is commissioned for the first
time, depending, however, on the various applications the requirements of which must be reviewed by the manufac-
turer/OEM.
This checklist should be retained and kept with the machine documentation to serve as reference during recurring
tests.
1. Have the safety rules ands regulations been observed in compliance with the directives/standards
applicable to the machine?
Yes
¡
No
¡
2. Are the applied directives and standards listed in the declaration of conformity?
Yes
¡
No
¡
3. Does the protective device comply with the required control category?
Yes
¡
No
¡
4. Is the access to the hazardous area/the hazardous point allowed only through the protective field
of the ESPE?
Yes
¡
No
¡
5. Have appropriate measures been taken to prevent or monitor the unprotected stay in the hazard-
ous area in the hazardous area/hazardous point protection (mechanical point-of-operation guard-
ing) and have these been secured against removal?
Yes
¡
No
¡
6. Are additional mechanical protective devices fitted and secured against manipulation which pre-
vent reaching over, under or around the ESPE?
Yes
¡
No
¡
7. Has the maximum stopping and/or post-run time of the machine been measured, specified and
documented (at the machine and/or in the machine documentation)?
Yes
¡
No
¡
8. Has the ESPE been mounted such that the required safety distance from the nearest point of dan-
ger has been achieved?
Yes
¡
No
¡
9. Are the ESPE devices properly mounted and secured against manipulation after adjustment?
Yes
¡
No
¡
10. Are the required protective measures against electric shock in effect (protection class)?
Yes
¡
No
¡
11. Has the control switch for resetting the ESPE protective device and/or for restarting the machine
been fitted and properly mounted and connected?
Yes
¡
No
¡
12. Are the outputs of the ESPE (OSSD) integrated in compliance with the required control category
and does the integration comply with the circuit diagrams?
Yes
¡
No
¡
13. Has the protective function been checked in compliance with the test notes of this documenta-
tion?
Yes
¡
No
¡
14. Are the required protective functions effective in every setting of the operating mode selector
switch?
Yes
¡
No
¡
15. Are the switching elements monitored, e.g. EDMs, valves which are activated by the ESPE?
Yes
¡
No
¡
16. Is the ESPE effective over the entire period of the dangerous state?
Yes
¡
No
¡
17. Once initiated, will a dangerous state be stopped when switching the ESPE on or off and when
changing the operating mode, or when switching to another protective device?
Yes
¡
No
¡
18. Has the notice label “Important Information” for the daily check been attached so that it is well
visible for the operator?
Yes
¡
No
¡
This checklist does not replace the initial commissioning, nor the regular inspection by specialist personnel.