O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07 | S I C K
Subject to change without notice
5 0
ELECTRICAL INSTALLATION
6.2.6
Serial interface connection of Bulkscan® LMS111
2
1
8
7
6
5
4
3
Fig. 32: Pin assignment of the "Data" connection (8-pins M12 male connector, A-cod-
ed)
Pin
Signal
Function
1
RxD
Receiver RS232 (Host interface)
2
TxD
Transmitter RS232 (Host interface)
3
Reserved
Do not use!
4
Reserved
Do not use!
5
GND RS
Ground RS232
6
IN1
Switching input 1
7
IN2
Switching input 2
8
GND IN
Ground digital input 1 + 2
Tab. 10: Bulkscan® LMS111 Pin assignment of the “Data” connection (M12x8 male
plug, A-coded)
6.2.7
Connection of the digital inputs/outputs on Bulkscan® LMS111
1
2
3
4
5
6
7
8
Fig. 33: Pin assignment of the “I/O” connection (8-pins M12 female connector, A-
coded)
Pin
Signal
Function
1
ENC1
Encoder input 1
2
ENC2
Encoder input 2
3
GND ENC
Ground encoder inputs
4
OUT1 A
Switching output 1, contact A
5
OUT2 A
Switching output 2, contact A
6
OUT3 A
Switching output 3, contact A
7
OUT1...3 B
Switching output 1...3, contact B
8
OUT1...3 R
Switching output 1...3, resistor moni-
tored
Tab. 11: Bulkscan® LMS111: Pin assignment of the “I/O” connection (8-pins M12
female connector, A-coded)