3
SYSTEM DESCRIPTION
22
8022161-1B29 / V2-0/2021-04|SICK
T R A N S L A T I O N O F A N O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | Backup Assistance System
Subject to change without notice
Field
set
Switching inputs
Field shape, default size of
field 1
IN 1
IN 2
IN 3
IN 4
1
0
0
0
0
Rectangle*, segmented
L: 1 m, W: 2 m
2
1
0
0
0
Rectangle*, segmented
L: 1.25 m, W: 2 m
3
0
1
0
0
Rectangle*, segmented
L: 1.5 m, W: 2 m
4
1
1
0
0
Rectangle*, segmented
L: 1.75 m, W: 2 m
5
0
0
1
0
Rectangle*, segmented
L: 1 m, W: 2 m
6
1
0
1
0
Rectangle*, segmented
L: 1.25 m, W: 2 m
7
0
1
1
0
Rectangle*, segmented
L: 1.5 m, W: 2 m
8
1
1
1
0
Rectangle*, segmented
L: 1.75 m, W: 2 m
9
0
0
0
1
Rectangle*, segmented
L: 1 m, W: 2 m
10
1
0
0
1
Rectangle*, segmented
L: 1.25 m, W: 2 m
11
0
1
0
1
Rectangle*, segmented
L: 1.5 m, W: 2 m
12
1
1
0
1
Rectangle*, segmented
L: 1.75 m, W: 2 m
13
0
0
1
1
Rectangle*, segmented
L: 1 m, W: 2 m
14
1
0
1
1
Rectangle*, segmented
L: 1.25 m, W: 2 m
15
0
1
1
1
Rectangle*, segmented
L: 1.5 m, W: 2 m
16
1
1
1
1
Rectangle*, segmented
L: 1.75 m, W: 2 m
L = length, W = width
* Default setting, starting shape can be modified as required
For the BAS driver assistance system, using field set 9 is mandatory
(see chapter
6.3.1 Opening field set with monitoring fields
Tab. 3: Field set factory settings - switching inputs
Field set factory
settings - switching
inputs