12
Troubleshooting
12.1
General faults, warnings, and errors
General faults are subdivided into warnings and errors. Current measured values as
well as respective warning messages continue to be output when there are warnings.
Measurement is no longer possible when there are faults and measured value
0
and
the respective error value are therefore output. If there is an error, the device continues
to extrapolate measured values no later than when the error suppression time set in
ErrRej
expires. During this time, the
WrnPlb
plausibility warning is output. If measurement
is still not possible after the error suppression time expires, measured value
0
and the
associated error message are output.
Warnings and errors are signaled via the
PWR
LED and can be read in the main menu
as long they are active. Warnings and errors can also be output via the multi-functional
outputs or the fieldbus interface via the SOPAS ET configuration software. They are not
stored on the device.
NoWrn
or
NoErr
is displayed in the main menu during fault-free
operation.
The
PWR
LED signals the device status.
NOTE
Possible faults and corrective actions are described in the tables below for trouble‐
shooting. In the case of faults that cannot be rectified using the description below,
please contact the manufacturer. See the back page for relevant contact details.
12.2
Device status (LED PWR)
Table 36: LED status indicator
Display
Fault
Measures
The
PWR
LED
does not light up.
No operation.
Device is defective.
Check the supply voltage.
Return the device for repairs.
The
PWR
LED
flashes orange.
A warning is present.
For possible causes and correct‐
ing them
.
The
PWR
LED
flashes red.
An error is present.
For possible causes and correct‐
ing them
.
12.3
Warning messages
An active warning is indicated by an orange flashing
PWR
LED. The warning can be read
in the main menu
.
Table 37: Warning messages
Display in the
main menu
(meaning)
Possible causes
Troubleshooting
NoWrn
No warning
-
12
TROUBLESHOOTING
82
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK