7
Operation
NOTICE
Device parameterization should not be carried out via the display, but exclusively for
the fieldbus interface with the help of the controller-specific project planning tool,
"Device project planning", page 53
NOTICE
Pushbutton damage due to improper handling!
Improper handling of the pushbuttons can damage them. This will make operation
difficult or impossible.
■
Only operate the pushbuttons with your fingers or a suitable pointing device.
■
Do not operate the pushbuttons using sharp or hard objects.
NOTE
For basic instructions for the display and control elements,
. Pressing the
pushbutton for more than 2 seconds switches
from
measured value display
to
menu display
operating mode.
For the overall menu structure,
NOTE
Parameters set using the operating buttons are not permanently saved until the system
jumps back to the measured value display. Depending on the menu level, it jumps back
if the
is pushed several times or automatically if no button is pressed for longer
than 90 seconds. Depending on the changed parameter, the device restarts when
switching to the measured value display, which causes a brief interruption in fieldbus
communication.
7.1
Parameter description
7.1.1
Main menu
The distance value is shown in the display by default. With the
pushbutton, you can
switch from the distance value display to the
bar graph level
display and other process
values.
You can scroll through the process values in the main menu using the
and
pushbuttons.
Table 9: Process values
Process values
Description
Distance value
Display of distance value in mm
Bar graph level
Display of the received signal level as a bar graph
Numerical level
Display of the received signal attenuation as a numerical value
see "Received signal level", page 28
Temperature
Display of the internal device temperature
Laser operating hours
Display of the operating hours of the laser diode
Warnings
Displays the pending warnings. If there is a warning pending, the
PWR
LED flashes orange. If there are no warnings pending,
NoWarn
is displayed,
see "Warning messages", page 82
OPERATION
7
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP