Attribute ID
Function
Detailed descrip‐
tion
Acc
ess
Data type
Content/meaning
0x0F
Product ID
R
STRG
Respective product type code
0x10
User ID
R/W STRG
Reserved (max. 32 characters)
0x11
Operating status
R/W UINT
0 = Initialization
1: Idle
2: Execute
3: In use by user
0x6A
Error code
R/W UINT
Read: Last error code write any
value: delete last error code
0x6C
Threshold
Near
R/W UINT
-32,768 ... 32,767 (default: depend‐
ing on sensor type)
0x6D
Far
R/W UINT
-32,768 ... 32,767 (default: depend‐
ing on sensor type)
0x6E
Output hysteresis
R/W UINT
0 ... 32,767 (default: depending on
sensor type)
0x6F
Calculation flags
R/W UINT
0: No calculation
1: Calculation
0x70
Calculation coefficient addi‐
tion
R/W UINT
-10,000 ... 10,000 (default: 0)
0x71
Calculation coefficient multi‐
plication
R/W UINT
-10,000 ... 10,000 (default: 1)
0x72
Calculation coefficient divi‐
sion
R/W UINT
1 ... 32,767 (default: 1)
0x73
Monitor cumulative values
R/W UINT
Field bus channel 2 data selection
(0: Head2,
1: Cumulative value)
0x74
Cumulative values
Head1
R/W UINT
0: None
1: Add
2: Subtract
3: Difference
0x75
Head2
R/W UINT
0x76
Left unit Head1
R/W UINT
0x77
Left unit Head2
R/W UINT
0x78
I/O polarity
R/W UINT
0: PNP (N/O / Normally open)
1: NPN (N/O / Normally open)
2: PNP (N/C / Normally closed)
3: NPN (N/C / Normally closed)
0x79
Output selection
Out1
R/W UINT
0: Off
1: Calculated GO
2: Calculated LO
3: Calculated HI
4: Head 1 GO
5: Head 1 LO
6: Head 1 HI
7: Head 2 GO
8: Head 2 LO
9: Head 2 HI
0x7A
Out2
R/W UINT
0x7B
Out3
R/W UINT
0x7C
Selection of external
Input
R/W UINT
0: Off
1: Teach-in (rising: far, falling: near)
2: OBSB teach-in
3: Zero reset
4: Laser off
0x7D
Selection of analog output
R/W UINT
0: Off
1: Calculated
2: Head 1
3: Head 2
OPERATION
7
8024950/2019-11-04 | SICK
O P E R A T I N G I N S T R U C T I O N S | WI180C-EN
33
Subject to change without notice