Figure 8: Monitoring case 1 with field set 1
Figure 9: Monitoring case 2 with field set 2
3.3.7
Simultaneous monitoring
The safety laser scanner can monitor several field sets in one monitoring case (e.g.
hazardous area to the left and hazardous area to the right). The field sets can affect
different safety outputs in variants with several safety outputs.
For example, they can protect 2 machines with only one safety laser scanner.
In order to configure simultaneous monitoring, assign several field sets to a monitoring
case in Safety Designer,
see "Assigning field sets", page 99
3
PRODUCT DESCRIPTION
20
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK
Subject to change without notice