background image

 

 

 

 

 INSTALLATION 

 

 

2.a

 PUMP MODULE 

 

The power supply must come from a different 
network than the air conditioner supply. 

Disconnect the power supply before installation. 

The power cable must be connected by a qualified professional complying with the standards in force 
in the country. 
Use only the cable 3 drivers supplied with a protection 10 A on the line. 
This power supply cable must be grounded. 
(standard  NFC  15100  lays  down  the  installation  of  a  high  sensitivity  differential  circuit  breaker  for 
dwelling units  (30 m A)) 
In  case  of  doubt  and  for  any interventions  concerning  electrical  connection, it is  preferable  to  call a 
qualified professional. 
SICCOM would not be held responsible for possible damages caused by a improper installation 
 If the power cable is damaged, it should be replaced by the manufacturer, its after-sales service or 
similarly qualified persons in order to avoid any danger. 
 

 
 
 
 
 
 
 
 
 
 

 

Installation of the pump module. 

 

The pump module may be installed in the air conditioner, in a chute (see diagram, opposite) or in the 
false ceiling. A space must be left around the pump module for it to cool in the event of prolonged 
operation. The pump module should not be covered (no insulation, no expanding foam, etc.). The 
discharge tube must be 6 x 9 mm in diameter. Use the hose clamp (supplied) to securely fasten the 
discharge hose to the pump. 

Make sure to observe the flow direction indicated by the arrow on 

the pump module.  

 

2.b

 DETECTION MODULE.  

 

The flexible elbow (supplied) allows connection of the detection module to the air conditioner tray. 
Suction is via the 1.50-meter flexible hose having a diameter of 6 x 9 mm (not supplied). Use the two 
hose clamps (provided) to securely fasten the flexible hose to the detection and pump modules  

 
 
 
 
 
 
 
 

 

Installation of the detection module. 

 

For  the  MAXI  ECO  FLOWATCH®,  the  detection  module  must  be  installed  and  fastened  in  a 
horizontal position with the velcro adhesive support (supplied). 

The  outlet  discharge  tube  of  the  pump  module  must  always  be  higher  than  the  detection 
module.

  In  other  case,  it  is  necessary  to  connect  the  outlet  discharge  tube  to  another  tube  of  a 

higher  diameter  in  order  to  prevent  siphoning.  Detailed  information  is  available  from  your  nearest 
wholesaler.  

 

 

OPERATION 

 

Check  that  the  maximum  water  level  in  the 
condensate  tray  is  higher  than  the  cover  level 
in the detection unit, to prevent the condensate 
tray overflowing before the alarm activates. 
Before  finishing  the  installation,  it  is  requested 
to  test  the  correct  operation  of  the  condensate 
removal pump. 

 

Never  try  to  run  the  pump  “dry”  without 
water (pump destructive)  

  Rinse  thoroughly  the  condensate  water 

tray  in  order  to  eliminate  all  metallic 
particles  and  foreign  bodies 

before 

connecting the detection unit

.  

  Position  the  detection  unit  in  order  to 

collect  the  condensate  from  the  air 
conditioner 

  Pour  water  into  the  condensate  tray  of 

the air conditioner without overfilling 

  Check  the  pump  starts,  pumps  water, 

then stops  

 

 

3.a

 MAINTENANCE. 

 

Any  maintenance  on  the  condensate  pump 

MUST  BE  DONE  WITH  THE  POWER  SUPPLIED 

SWITCHED OFF.  

At the beginning of the season, or regularly if the air conditioner is used all year long: 
Remove  the  cap  of  the  detection unit  and  the  magnet.  Clean inside the  detection  unit  and  the  float 
with water containing 5% bleach. 

Rinse thoroughly after use of a cleaning product.

  

Then  replace  the  float  with  the  black  spot  facing  up,  and  the  filter.  Replace  the  cap,  always  in  the 
direction of origin and do a full operational test.  

 

 

3.b

 SAFETY 

 

  A thermal cut-out set with AUTO-RESET 

  Connect the earth wire of the pump 

  Product without alarm 

SICCOM  SAS  strongly  recommends  fitting  a  high  condensate  level  detector

  connected  to  an 

audio alarm (Buzzer) or a visual one (Indicator) to avoid any overflow or interruption of refrigeration in 
the event of an incident in the system or lack of maintenance. To do this, we recommend using the

 

SICCOM SAS ref DS1HTCC110 detector available from your retailer. 

 

 Warranty  

 

Your  pump  is  guaranteed  to  be  in  perfect  working  order  at  delivery.  The  model  MAXI  ECO 
FLOWATCH

®

  Ref  DE40LCC300  is  guaranteed  for  one  year  (12  months)  from  the  SICCOM  SAS 

billing  date  against  all  operating  faults.  In  the  case  of  detection  of  a  fault,  customers  not  located  in 
France must return the pump postage paid to the nearest SICCOM distributor. All products returned 
will be subject to a complete analysis of origin and operation in relation to its traceability code and the 
technical  performances  ascertained.  If  it is  determined  that  the  fault is  unrelated  to incorrect  use  of 
the pump and that the installation instructions have been complied with, the product will be repaired 
or replaced. 

 

RESTRICTIONS: 
Any implicit guarantee will be limited to the duration of the express guarantee specified above. 
In  all  cases,  the  responsibility  related  to  the  SICCOM  SAS  warranty  is  limited  to  the 
replacement  or  repair  of  the  product  supplied  plus  the  cost  of  its  transport  to  the  original 
delivery location. 
N

EITHER  THE  VENDOR  NOR  THE  MANUFACTURER  IS  RESPONSIBLE  FOR  INJURIES  OR  DAMAGES 

DIRECTLY  RELATED  TO  THE  PRODUCT  OR  SUBSEQUENT  TO  ITS  USE 

(

INCLUDING  BUT  NOT  LIMITED 

TO LOSS OF PROFIT

,

 LOSS OF TURNOVER

,

 DAMAGE TO GOODS OR PERSONS DIRECTLY RELATED TO 

THE  PRODUCT  OR  RESULTING  FROM  ITS  USE

)

  OR  ANY  PREJUDICE  ARISING  FROM  THE  USE  OF  OR 

INABILITY TO USE THE PRODUCT

.

 

T

HE USER AGREES THAT THIS SITUATION IS WITHOUT RECOURSE 

OR COMPENSATION

 

THE WARRANTY WILL BE INVALIDATED IN THE FOLLOWING CASES: 

 

-

 

Pump motor cover opened 

-

 

Product connected to an incorrect supply voltage 

-

 

Tank cable cut 

-

 

Pump used dry (no liquid supply) 

-

 

Pump used to circulate liquid other than condensates. 

-

 

Incorrect use of the pump by the customer 

 

Before  using  the  product,  the  user  must  determine  whether  it  is  compatible  with  his  or  her 
intended  use  of  the  product.  They  will  be  responsible  for  all  risks  and  legal  implications 
resulting from its use or installation. 

 SICCOM  SAS  reserves  the  right  to  modify  the  product  completely  or  partially  without  first 
informing its customers about it 

CONFORMITY CERTIFICATE SICCOM SAS

 

Z.I. Les Bordes 2 rue Gustave Madiot - 91070 Bondoufle - FRANCE declare that the MAXI ECO FLOWATCH

® 

is in 

conformity with :  
• EN 60 335-1 

D  

 

 HINWEIS 

 

Mit geringem Platzaufwand kann unsere MAXI ECO FLOWATCH 

®

 einfach in jede Klimaanlage 

eingebaut werden (Decken-, Wand- oder Konsole-Anlage), deren Kälteleistung 30 KW (102000 Btu, 
8,5 Tonnen) nicht überschreitet. Die MAXI ECO FLOWATCH 

® 

 besteht aus den zwei folgenden 

Teilen :  

 

der Pumpeneinheit  

 

dem Schwimmerschalter  

(2 Niveaus Pumpen-Aus, Pumpen-Ein) 

 

Allgemeine technische Daten : 

 

Maximale Leistung :  

 

40 Liter / Stunde 

Maximale Fördermenge :    

10 meter  

Maximale Einsaugung :    

2 Meter

 

Einspeisung der Pumpeneinheit : 

220-240 V 50/60 Hz 

Leistungsaufnahme der Pumpe :  

16W 

Relative Einschaltdauer:    

100% 

 

Thermische Sicherung :    

Ja. Mit auto-restart.

 

Arbeitstemperatur : 

 

5°C bis 45°C 

Maximale Temperatur der Flüssigkeit:  35°C 
Schutzklasse : 

 

IP20

 

 

 
 
 
 

 

INSTALLATION 

 

 

2.a

 DIE PUMPENEINHEIT.  

 

Die Einspeisung muss von einem anderen Netz als von der Klimaanlage herkommen.  
Vor der Installation das Klimagerät spannungsfrei schalten. 
Der  Anschluss  des  Stromversorgungskabels  muss  von  einem  qualifizierten  Fachmann  unter 
Berücksichtigung der geltenden Normen des Landes durchgeführt werden. 
Dieses Netzkabel muss geerdet sein.

 

 

Nur das schwarze Kabel 3 gelieferte Fahrer zu benutzen und hat ein Schutz 10 auf der Linie. 
(Die  Norm  NFC  15100  verlangt  für die Wohnung  einen  hochempfindlichen  FI-Schutzschalter  (30  m 
A).) 
Bei Zweifeln und bei allen elektrischen Eingriffen wird empfohlen, einen qualifizierten Fachmann 
heranzuziehen 
SICCOM  SAS   haftet  nicht  für  eventuelle  durch  eine  unsachgemäße  Installation  entstandene 
Schäden. 
Wenn das Versorgungskabel beschädigt ist, muss es vom Hersteller, seinem Kundendienst oder 
ähnlich qualifizierten Personen ersetzt werden, damit keine Gefährdung entsteht. 
 
 
 
 
 
 

Use only the supplied 3 core cable: 

 

Blue / Neutral 

 

Brown / Line 

 

green / Earth  

 

Содержание MAXI ECO FLOWATCH DE40LCC300

Страница 1: ...er les condensats du climatiseur installé Verser de l eau dans le bac du climatiseur sans excès Vérifier la mise en marche de la pompe et constater l évacuation de l eau par la pompe puis l arrêt de celle ci 3 a ENTRETIEN Toute intervention sur la pompe de relevage de condensats DOIT ETRE EFFECTUEE HORS TENSION En début de saison ou régulièrement si la pompe est utilisée toute l année Enlever le c...

Страница 2: ...this we recommend using the SICCOM SAS ref DS1HTCC110 detector available from your retailer Warranty Your pump is guaranteed to be in perfect working order at delivery The model MAXI ECO FLOWATCH Ref DE40LCC300 is guaranteed for one year 12 months from the SICCOM SAS billing date against all operating faults In the case of detection of a fault customers not located in France must return the pump p...

Страница 3: ...EM GEWINN UMSATZVERLUSTEN SCHÄDEN AN GÜTERN ODER PERSONEN IN DIREKTEM ZUSAMMENHANG MIT DEM PRODUKT ODER AUFGRUND DESSEN NUTZUNG ODER FÜR BEEINTRÄCHTIGUNGEN AUFGRUND DER NUTZUNG ODER UNMÖGLICHKEIT DER NUTZUNG DES PRODUKTES DER BENUTZER ERKENNT AN DASS ES FÜR DIESEN FALL WEDER RECHTSMITTEL NOCH SCHADENSERSATZ GIBT IN FOLGENDEN FÄLLEN VERLIERT DIE GARANTIE IHRE GÜLTIGKEIT Öffnung des Pumpengehäuses A...

Страница 4: ...n torno al bloque de bomba para permitir que se enfríe en caso de funcionamiento prolongado El bloque de bomba no debe ser cubierto ni aislante ni espuma de poliuretano etc El tubo de descarga debe poseer un diámetro 6 x 9 mm Utilizar una abrazadera de sujeción incluida para fijar de forma duradera el tubo de descarga a la bomba Respetar el sentido de flujo que indica la flecha del bloque de bomba...

Страница 5: ...que o reservatório no devido lugar para recolher os condensados do aparelho de ar condicionado instalado Verta água no recipiente do aparelho de ar condicionado mas sem exceder Verifique a colocação em funcionamento da bomba e observe a evacuação da água pela bomba e em seguida a paragem da mesma 3 a MANUTENÇÃO Qualquer intervenção na bomba de evacuação de condensados DEVE SER EFECTUADA SEM TENSÃO...

Страница 6: ...ą przesyłką do najbliższego dystrybutora SICCOM SAS Wszelkie zwrócone produkty zostaną poddane kompletnej analizie pochodzenia oraz działania w powiązaniu z kodem śledzenia oraz zbadanymi osiągami technicznymi W razie stwierdzenia braku awarii związanej z nieprawidłowym użytkowaniem pompy oraz jeśli przestrzegano procedury instalacji produkt zostanie wymieniony lub naprawiony OGRANICZENIA Wszelka ...

Страница 7: ...ерелива и остановить производство конденсата в случае поломки устройства или отсутствия его обслуживания Рекомендуется использовать датчик SICCOM SAS позиция DS1HTCC110 который можно приобрести у наших дистрибьютеров ГАРАНТИЯ Гарантируется работоспособность насоса на момент отгрузки модель MAXI ECO FLOWATCH Ref DE40LCC300 гарантия 1 год 12 месяцев с момента приобретения В случае обнаружения дефект...

Отзывы: