![Sicam SBM 855 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/sicam/sbm-855/sbm-855_original-instructions-manual_1263672032.webp)
656 229
2010-11-22
|
Sicam snc società unipersonale
32 | SBM 855 | Fitting and removing the fl ange
en
5.
Fitting and removing the
flange
Fitting of the flange is necessary in the following
situations:
Commissioning
When changing the type of flange
(centering flange, universal flange, special flange)
When changing the type of wheel
(passenger car - truck)
!
Balancing accuracy will be impaired if the flange has
not been properly fitted to the shaft.Before fitting the
flange, clean and degrease (remove corrosion protec-
tion) the cone of the shaft and the flange opening.
5.1
Removing the flange
1.
Slacken off the hexagon socket head bolt.
651002-04 _Rf
2.
Unfasten the flange by tapping with a rubber-headed
hammer on the cone end.
3.
Pull the flange off the cone.
651002-06 _Rf
"
Flange detached.
6.5
Compressed air connection
1.
Connect the SBM 855 to the compressed air supply.
651003-05 _Rf
2.
Set a pressure of between 8 bar and 12 bar.
First pull the pressure reducer (red knurled
screw) upwards and then turn to set the pressure
to between 8 and 12 bar.
Check the pressure on the pressure gauge.
!
The pressure must never exceed 12 bar!
6.6
Calibration of SBM 855
!
Calibration must be performed after initial commis-
sioning.
1.
Flange calibration.
2.
SBM 855 calibration.
3.
Perform reference measurement.
i
Calibration is described in Section 12.4