5.  Specifications   

 

Operating Voltage 

9-28V DC 

User Capacity 

2000 

Card Reading Distance 

3-6 cm 

Active Current 

60mA 

Idle Current 

25±5 mA 

Lock Output Load 

Max 3A 

Alarm Output Load 

Max 20A 

Operating Temperature 

-45

℃~

60

 

Operating Humidity   

10%- 90% RH 

Waterproof 

Conforms to IP68 

Adjustable Door Relay time 

0 -99 seconds 

Adjustable Alarm Time 

0- 3 minutes 

Wiegand Interface 

Wiegand 26 bit 

Wiring Connections 

Electric Lock, Exit Button, External Alarm 

6.  Installation 

l

 

Remove the back cover from the keypad using the supplied special screw driver 

l

 

Drill 2 holes on the wall for the Self tapping screws and I hole for the cable 

l

 

Put the supplied rubber bungs to into the two holes 

l

 

Fix the back cover firmly on the wall with 2 Self tapping screws 

l

 

Thread the cable through the cable hole 

l

 

Attach the keypad to the back cover.

 

 

 

 

 

Содержание Standalone Keypad Access Control

Страница 1: ...Standalone Keypad Access Control User Manual...

Страница 2: ...programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits To add a PIN user...

Страница 3: ...t short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and...

Страница 4: ...ds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm 6 Installation l Remove the back cover from the keypad using the suppl...

Страница 5: ...d 12V 12V DC Regulated Power Input Black GND 12V DC Regulated Power Input Blue NO Relay normally on end Connect positive electric lock Purple COM Relay Public end connect GND Orange NC Relay Closed en...

Страница 6: ...Di Alarm Bright Alarm 11 Detailed Programming Guide 11 1 User Settings To enter the programming mode Master code 999999 is the default factory master code To exit from the programming mode Note that...

Страница 7: ...alternative way to enter cards using User ID Allocation In this method a User ID is allocated to a card Only one user ID can be allocated to a single card 1 ID number Read card User can be added conti...

Страница 8: ...PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that th...

Страница 9: ...being 1 minute To disable door open detection Factory default 6 0 To enable door open detection 6 1 Alarm output time To set the alarm output time 0 3 minutes Factory default is 1 minute 5 0 3 Keypad...

Страница 10: ...10...

Отзывы: