Please read the manual carefully before use this unit   

1.  Packing List 

Name 

  Quantity 

Remarks 

Keypad 

      1 

 

User manual 

      1 

 

Screw driver   

      1 

Φ20mm×60mm

,

Special for keypad

 

Rubber plug 

      2 

Φ6mm×3

0 mm, used for fixing 

Self tapping screws 

      2 

Φ4mm×28 mm

, used for fixing 

Star screws

 

      1 

Φ3mm×6mm

, used for fixing 

Please  ensure  that  all  the  above  contents  are  correct.  If  any  are  missing  please  notify  the 

supplier of the unit.   

2. Quick Reference Programming Guide

 

To enter the programming mode 

*    Master code    # 

999999 is the default factory master code   

To exit from the programming mode 

  *   

Note that to undertake the following programming the master user must be logged in 

To change the master code 

0    New code    #    New code    # 

The master code can be 6 to 8 digits   

To add a PIN user. 

 

1    User ID number    #    PIN #   

The  ID  number  is  any  number  between  1  &  2000.  The 

PIN  is  any  four  digits  between  0000  &  9999  with  the 

exception of 1234 which is reserved. Users can be added 

continuously without exiting programming mode 

To add a card user 

1    Read Card    # 

Cards  can  be  added  continuously  without  exiting 

programming mode 

To delete a PIN or a card user.   

2    User ID number    #    for a PIN user or       

2    Read Card    #    for a card user     

Users  can  be  deleted  continuously  without  exiting 

programming mode 

To unlock the door for a PIN user 

Enter the PIN then press # 

Содержание Standalone Keypad Access Control

Страница 1: ...Standalone Keypad Access Control User Manual...

Страница 2: ...programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits To add a PIN user...

Страница 3: ...t short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and...

Страница 4: ...ds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm 6 Installation l Remove the back cover from the keypad using the suppl...

Страница 5: ...d 12V 12V DC Regulated Power Input Black GND 12V DC Regulated Power Input Blue NO Relay normally on end Connect positive electric lock Purple COM Relay Public end connect GND Orange NC Relay Closed en...

Страница 6: ...Di Alarm Bright Alarm 11 Detailed Programming Guide 11 1 User Settings To enter the programming mode Master code 999999 is the default factory master code To exit from the programming mode Note that...

Страница 7: ...alternative way to enter cards using User ID Allocation In this method a User ID is allocated to a card Only one user ID can be allocated to a single card 1 ID number Read card User can be added conti...

Страница 8: ...PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that th...

Страница 9: ...being 1 minute To disable door open detection Factory default 6 0 To enable door open detection 6 1 Alarm output time To set the alarm output time 0 3 minutes Factory default is 1 minute 5 0 3 Keypad...

Страница 10: ...10...

Отзывы: