Siamp Optima 49 Скачать руководство пользователя страница 2

Fig A. 
Stirrup in position 7.
(number 6 will be visible)

Fig B. 
Lift Rod in position 5 
(4 holes visible above)

Overflow tube pre-cut at D

Fig C. 
Residual Water set at 0 

Fig D. 
Short flush cursor set at 10 

Vitra S20 Troubleshooting 

Sticking or not flushing
Passing water

Содержание Optima 49

Страница 1: ...on is correct check the valve settings are still in the factory set positions detailed in the table right If the problem persists please contact Siamp Aftersales on 0161 681 2120 or aftersales siamp co uk No Description Setting Figure 1 Stirrup Position 7 number 6 will be visible A 2 Lift Rod Position 5 4 holes above will be visible B 3 Overflow Factory set D will be visible B 4 Residual Water 0 C...

Страница 2: ...umber 6 will be visible Fig B Lift Rod in position 5 4 holes visible above Overflow tube pre cut at D Fig C Residual Water set at 0 Fig D Short flush cursor set at 10 Vitra S20 Troubleshooting Sticking or not flushing Passing water ...

Страница 3: ...h Long flush Optional escutcheon not always supplied Lift rod Residual sliding valve Strainer Strainer nut Pan gasket Strainer gasket Valve gasket Stirrup catch clip Overflow Stirrup Ref 50 5498 01 a b c d e f g h i k l m GB Short flush cursor j N 50 ...

Страница 4: ... H of cistern Diameter D Diameter D of hole in lid of hole 18 to 38 mm in lid and 38 to 45 to 50 mm 44 mm 11 430 to 417 448 to 435 10 416 to 405 434 to 423 9 404 to 393 422 to 411 8 392 to 381 410 to 399 7 380 to 369 398 to 387 6 368 to 357 386 to 375 5 356 to 345 374 to 363 4 344 to 333 362 to 351 3 332 to 321 350 to 339 2 320 to 309 338 to 327 1 308 to 297 326 to 315 Mini 296 to 282 314 to 300 N...

Страница 5: ...ock see overleaf Note The max water level should be 20 mm lower than the overflow tube l To adjust the water level of the short flush slide the cursor along j Immerse the cursor of 40 mm Note The closer the cursor is to 18 the more water will be flushed Once the set up has been completed put on the lid on the cistern If the hole in the lid D is 38 mm and 45 mm remove the escutcheon b Position the ...

Страница 6: ...et Adjustment screw Locking nut Locking nut Gasket filter Adjustment screw Filter Membrane Membrane Manually screw the backnut until it is in contact with the ceramic If necessary give an extra quarter turn maximum N B Excessive tightening can damage the mechanism and would not be covered by the guarantee Ensure tightness of connection to cistern with filter gasket WARNINGS 1 Do not overtight in a...