Well sounders «DU-1»
of the device, the identification plate of the device is marked with an
"X" sign indicating special conditions of safe operation.
The "X" symbol in the explosion proof marking indicates
special conditions for safe operation:
1) Do not open the instrument cover and therefore the battery
compartment cover in hazardous areas;
2) Do not replace the battery and operate the computer in hazardous
areas;
3) Do not charge the battery in explosion hazard area;
4) Only the types of batteries specified in the manufacturer's
technical documentation may be used as power sources;
5) Constituents and circuits ensuring intrinsically safe design shall
not be repaired and in case of failure shall be replaced by new ones
supplied by the manufacturer;
6) The device's operability is maintained at ambient temperature
from minus 40 to plus 50
о
С.
The maximum temperature of overheating of components and
connections in the circuit diagram during normal operation is 15 °C
max. Thus, the surface temperature of conductors and elements
during operation and at maximum operating temperature plus 50 °
C is not more than 65 ° C. Device enclosures are made with the
degree of protection against external influences not lower than IP54
according to GOST 14254-2015.
6.2. Measures to ensure and keep the device explosion-
proofness during the assembly, disassembly and repair of the
device.
6.2.1. Measures to ensure explosion-proofness
before the
production process:
- The elements used in the protective component of “Fib” are
subjected to an acceptance test:
- resistors are tested for their nominal resistance;