TECHNICAL DATA SHEET FOR INDIRECT FIRED OIL HEATERS – 55 kW MODEL
Thermal Specifications
Airflow Specifications
Electrical Specifications
Maximum Thermal Power (Diesel Oil)
Air Flow Rating
Rated Voltage
Consumption
Kg/hr
at 3°C (37F)
4,16 m³/h
2500 m³/h
1475 ft³/min
V/Hz
110/60
U.S. gal/hr
1,29
Efficiency
%
87,10 Fan
Rated Current
Power Input
kcal/hr
45217 mm
350 mm
14 in
A
7,0
kW
52,58 Blade #
3 sickle-shaped
BTU/hr
180868 Pitch
18°
Rated Power
Power Output
kcal/h
39384
W
460
kW
45,80 Temperature Rise (Delta)
BTU/hr
157536
at 20°C (68 F)
73°C
131 F
Motor Power
Fuel Pressure
W
430
12 bar 175 psi Noise Level
at 1 m
at 2 m
dB(A) average
75
73
Rotational Speed
Smoke Index
with original hood
rpm
3400
1,00
Air Lock Adjustment
Nozzle Type
Fuse
mm
4,0 Manufacturer
DANFOSS
A
15 slow-blow
Type
60° H
Maximum Thermal Power (Kerosene)
Flow Rate
GPH
1,00
Size Specifications
Consumption
Kg/hr
3,81
Weight
Tank Capacity
Efficiency
%
87,10 Air Ducting
76 kg
167 lb
51 liters
14 U.S. gal
Power Input
kcal/hr
42006 Hose Diameter
Lenght
Outlet Diameter
kW
48,84
315 mm
12 in
1405 mm
55 in
308 mm
12 in
BTU/hr
168022 Maximum Hose Lenght
Width
Flue Diameter
Power Output
kcal/hr
36587
8 m
25 ft
620 mm
24 in
150 mm
6 in
kW
42,54
Height
BTU/hr
146347
790 mm
31 in
Fuel Pressure
psi
12,00
*oil gross heating value Kcal/kg
10869,44
Package Specifications
Air Lock Adjustment
*kerosene gross heating value Kcal/kg
11.025,08
Lenght
1470 mm Height
830 mm
mm
7,00 according to standard prEN 13842:2002
Width
530 mm Weight