E7014
30
ORDERING CODE
(**): insert value (in seconds)
(Parameter 25) Some selection are compatible with them-self (see “Size”), if need more possible
selection (T e C, 2 e C o A, etc) the priority code must the following: expansion card, cabling, ignition
transformer and last the ESA TRAFO coupled.
NOTE: Based on the company’s policy aimed at a continuous improvement on product quality, ESA-PYRONICS reserves the right to bring
changes to the technical characteristics of this device without previous notice. Our catalog updated to the latest version is available on our web
site www.esapyronics.com and it is possible to download modified documents
WARNING: When operating, this combustion system can be dangerous and cause harm to persons or damage to equipment. Every burner
must be provided with a protection device that monitors the combustion. The installation, adjustment and maintenance operations should only
be performed by trained and qualified personnel.
2
6
7
8
9
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
1
11
20
12
2
3
13
21
4
22
5
14
6
23
15
7
24
25
16
8
17
9
18
26 27 28 29
10
19
26
27
28
29
see tab A
////
no expansion
Exp - 2
Exp - 3
Exp - 4
0
ESTRO
1
3
4
Cycle start
Estro - Q
Estro - B
B2
Inhibited
Comunication baudrate
3 minute
3M
from 0 to 99 seconds
(**)
Wait for manual reset (Standby)
S
Remote
R
D
Active only with lockout
F
MODBUS 2
Air ON / Off function
from 0 to 25 seconds
(**)
Main ON / Off function
M
A
Re-ignition enabled
K
Special version
Only one cycle repetition
R
Automatic reset
Standard
Enable
H
Pre wiring
Esa Trafo coupled box
With expansion Exp-3
C
High temperature function
R
4 minute
4M
from 0 to 99 seconds
Enable
F
Reaction time at flame loss
5
10
Version
Daily check shout off
Comunication timeout
Estro - A
A2
Enable (test every 24h)
D
0 seconds
8 seconds
1
Estro - C
C2
16 seconds
2
/
Q2
Air flow control mode
32 seconds
3
Continue or not present
C
64 seconds
4
Discontinue
D
128 seconds
5
Automatic ignition (Autostart)
A
Pulse
P
256 seconds
6
320 seconds
7
400 seconds
8
PrePurge
Digital Input function
480 seconds
9
Inhibited
/
2 minute
2M
Reset / Stop
B
Only stop
S
4800
4
4 minute
4M
Only reset
U
9600
9
T
19200
1
1st safety time
High temperature enabling
H
38400
3
Thermostat
Comunication protocol
Regolation delay time
ECS
E
from 0 to 25 seconds
(**)
Lock output
MODBUS 1
1
2
1st stage gas outlet type
Active with lockout and stop
B
Intermittent (continuos)
C
Spare
Local button
/
Stop / Reset
B
Behavior at flame loss
Stop/reset enabled from remote
R
Spare
Interrupted
/
Cycle repetition enabled
Y
Only reset
U
Lock-out stop
N
Only stop
S
/
Only one re-ignition
S
Reset number
0 - 9
Ignition transformer inside
T
A
115 Vac
1
Inhibited
/
With expansion Exp-2
2
Supply Voltage
3
With expansion Exp-4
4
PostPurge Flex
Fixed safety time
/
Expansion parameters
1st stage gas ignition type
230 Vac
2
Inhibited
/
Variable safety time
S
PostPurge time
From 0 to 9 seconds
0 - 9
see E7015
see E7016
(**)
From 10 to 20 seconds
A - K
2 minute
2M
3 minute
3M
tab A - Exp-2 Expansion parameters
Supply Voltage
Air pressure switch
Thermostat input
Air damper input
115 V ac
1
Inhibited
/
Inhibited
/
Inhibited
/
230 V ac
2
Puts in waiting phase
H
Enable
T
Remote serial control
Local digital control
L
24 V ac
4
Stop in lock-out status
L