background image

 

Manual_UK_K_K_rev. 1_10_2013   

 

 

 

 

 

 

pag. 25 

CE certificate

 

 

 

 

Содержание KALIENTE E

Страница 1: ...d MAINTENANCE Patio heaters models KALIENTE E M and SOLFLAME E M models KALOR M and SOLEIL M manual start up SIABS S r l ITALY Phone 39 02 90384081 E mail commerciale siabs it via Del Lavoro 7 Fax 39...

Страница 2: ...t ready to working suggestions 12 Put in operation and First Start up 13 17 position of heater handling and gas bottle positioning 13 and 14 suggested gas bottle 14 start up 15 17 Safety devices 18 Ma...

Страница 3: ...e appliance must be installed only in premises with adequate ventilation installation should be done in accordance with the Regulations in force in the country of destination to the state of art follo...

Страница 4: ...nd modification kits every time the gas bottle is replaced check that gasket of gas regulator is in correct position and works as requested you should check periodically the flexible gas pipe to check...

Страница 5: ...defects The guarantee does not cover problems due to carelessness incorrect setting misuse of the appliance or fortuitous accidents and not dependent on imperfection processing or defective materials...

Страница 6: ...echnical data do not remove placed inside the gas bottle compartment on the burner cover Apparatus type A1 Plate label example patio heater KALIENTE Electronic gas type G31 propane Essential features...

Страница 7: ...20 mbar G31 37 mbar RO C II 2H3 G20 G25 20 25 mbar G30 G31 28 30 37 mbar HU II 2H3B P G20 25 mbar G30 G31 30 mbar PL II 2E3B P G20 20 mbar G30 G31 37 mbar PL II 2E3P G20 20 mbar G31 37 mbar CH II 2H3...

Страница 8: ...I II 2H3P G20 20 mbar G31 37 mbar RO C II 2H3 G20 G25 20 25 mbar G30 G31 28 30 37 mbar HU II 2H3B P G20 25 mbar G30 G31 30 mbar PL II 2E3B P G20 20 mbar G30 G31 37 mbar PL II 2E3P G20 20 mbar G31 37 m...

Страница 9: ...g 9 OVERALL DIMENSIONS patio heaters KALIENTE KALOR SOLFLAME SOLEIL NOTE we recommend to make use of the 4 adjustable feet to ensure always optimal vertical position and avoid floor surface damage MIN...

Страница 10: ...By minimum distance of installation we mean the distance to be kept between the patio heater and any component potentially flammable We recommend to keep at least 0 5 mt between the cover top of the...

Страница 11: ...to give comfort in all spaces which need complete or partial heating SIABS patio heaters must be installed in partly protected areas it is not designed to be subject to direct action of atmospheric a...

Страница 12: ...fully pre assembled you have only to provide the gas bottle and the pressure reduction kit flexible pipe pressure reducer different from country to country to be assembled on site burner is fully mou...

Страница 13: ...1 HANDLING for all movements of the patio heater for secure and easier handling we recommend to use only SIABS device for transport handling optional named kit for transport fixing it to the lower pa...

Страница 14: ...r the fitting of the pressure reducer on tap of gas bottle and slowly open the tap of the gas bottle Picture 8 Picture 7 Picture 8 check with soapy water or equivalent material losses on the connectio...

Страница 15: ...e detection electrode will give positive input for total opening of the gas valve and then turning on the heater takes place one remote can manage more heaters on off level of power To switch off pres...

Страница 16: ...conds leave the knob and verify that the pilot device stays on repeat the operation if the pilot device goes out Picture 11 NOTE to switch off turn the knob to position 0 ZERO Picture 11 MANUAL VERSIO...

Страница 17: ...case you want to enjoy a different level of comfort or fit it to different external temperatures MANUAL version with pilot device on turn the knob towards MIN or MAX as on the plate Picture 11 until y...

Страница 18: ...id any leakage of gas The thermocouple placed on the ignition pilot detects the flame and locks the gas circuit if the heater turns off due to lack of gas or accidentally plus there is also a mechanic...

Страница 19: ...ould become necessary to replace the glass tube blackening important after a few years or accidental breakage proceed as follows wait until the patio heater is cold in all its parts remove upper cap 4...

Страница 20: ...to change type of gas e g from LPG to natural gas it is COMPULSORY to change the PRESSURE STABILIZER only for manual start up version and to change the plate label with technical data and place one w...

Страница 21: ...urns on then it C1 Fault with thermocouple C1 Replace thermocouple turns off as soon as you release the gas tap D No spark at pilot start up D1 Spark electrode damaged D1 Replace electrode D2 Spark ca...

Страница 22: ...ocouple of the flame or work C2 Fault with remote control C2 Replace remore control partially C3 Fault with command control C3 Replace command control D No spark at pilot start up D1 Fault with spark...

Страница 23: ...ocked A4 Replace anti tilt sensor B The burner turns on then it B1 Fault with thermocouple B1 Replace thermocouple turns off as soon as you release the tap version C No spark at C1 Spark electrode dam...

Страница 24: ...02EKAL12 ____ cables DC 0104EKAL12 ____ battery box 0105EKAL12 ____ remote control 0103EKAL12 ____ Patio heater KALIENTE SOLFLAME MANUAL glass pipe 001TOBF1200 ____ pilot complete 440 1221 13 ____ ele...

Страница 25: ...Manual_UK_K_K_rev 1_10_2013 pag 25 CE certificate...

Страница 26: ...Manual_UK_K_K_rev 1_10_2013 pag 26 Service sheet DATE and STAMP OPERATION NOTE DATE and STAMP OPERATION NOTE DATE and STAMP OPERATION NOTE DATE and STAMP OPERATION NOTE...

Страница 27: ...to appropriate separate collection centres of electric and electronic waste or return it to the dealer when purchasing a new device to be equivalent in terms of one to one The proper differentiated c...

Страница 28: ...rezzo MI ITALIA _______________________________________________________________ To contact us Phone 39 02 90384081 Fax 39 02 9029538 E mail commerciale siabs it Web page www siabs com Continuous devel...

Отзывы: