4.3 Corrective Maintenance

Situation

Cause

Resolution

NO PUMP DISCHARGE

•  Suction &/or discharge check 

valves not seating

•  Pump vapour locked
•  Suction or discharge line 

plugged/blocked

•  Clean or replace suction &/or 

discharge check valves

•  Open bleed plug & prime
•  Check for closed isolating valve
•  Check inlet and discharge lines for 

blockage

PUMP DOES NOT CYCLE •  Plunger stuck due to tight or 

dry seal

•  Process line pressure too high 

for unit selected

•  Blown fuse
•  No power supply to DC motor 

drive

•  Timer switch in OFF position
•  Timer set to minimum cycle 

rate

•  Check seal, if swollen , check 

chemical compatibility and replace

•  Check selection and ensure 

discharge line is not blocked

•  Check and replace fuse in DC 

supply. If this condition repeats 
itself, check the drive mechanism 
for seizure.

•  Check and connect correct power 

supply

•  Set switch to CONTINUOUS for 

testing

•  Adjust timer accordingly

SHORT SEAL LIFE

•  Nick, Burr or scratches on 

plunger

•  Seal &/or plunger materials not 

compatible with chemical being 
injected

•  Lack of lubricant
•  Incorrect lubricant or chemical 

crystallising on plunger and 
scoring seal/plunger

•  Replace plunger
•  Refer to chemical compatibility 

charts or contact Solar Injection 
Australia

•  Maintain visible lubricant level in 

reservoir.

•  Change lubricant to be compatible 

with chemicals being pumped.

Содержание SIA-12-L35-CR-TS-9050

Страница 1: ...MANUAL INSTALLATION OPERATION MAINTENANCE SiA CHEMICAL INJECTION PUMP...

Страница 2: ...PRIGHT LAWS REPRODUCTION EITHER PARTIAL OR COMPLETE IS PROHIBITED UNLESS PRIOR CONSENT HAS BEEN GIVEN IN WRITING BY SOLAR INJECTION 1 SIA 12 L35 CR TS 6050 GENERAL ASSEMBLY SIA 12 L35 CR TS 6050 10 F...

Страница 3: ...TOR 1 15 A 1 2 3 4 5 SIA 12 L35 CR TS 9050 6 5 4 3 2 1 B C D E F F E D C B A NO MANUAL REVISIONS ALLOWED A3 592 Tarragindi Road Salisbury Qld 4107 Tel 61 7 3277 8822 SCALE STATUS SIZE SHEET OF DWG NO...

Страница 4: ...8 NPT VENT SCREEN 1 13 40063 B CHECK VALVE 1 14 DELRIN 40055 2 BACKUP 0 375 2 15 UHMWPE 40065 2 4 MAIN SEAL 0 375 1 16 Steel 40056 RETURN SPRING 1 17 A 1 2 3 4 5 6 B C D E F F E D C B A A3 592 Tarrag...

Страница 5: ...n Environment 2 2 Installation Step by Step SECTION 3 PUMP OPERATION 3 0 Operating Pump With SiA Timer Controller 3 1 Chemical Injection Flow Rate Adjustment SECTION 4 MAINTENANCE 4 0 Routine Maintena...

Страница 6: ...rsized sealed bearings so as to eliminate all overhung loads This greatly increases the life of the gear motor s gearbox By applying a rotary force to the end of the crank shaft the force is transmitt...

Страница 7: ...his manual for part numbers specific to your pump Voltage Watts Ratio Gearbox Type Hazardous Area Certifications Standard 12 24 120 240 220 415 20 40 60 90 120 150 50 75 150 Spur N A Standard BLDC 12...

Страница 8: ...FUSE REQUIRED 12 Volt 24 Volt High Efficiency 150 100 IEC NA NA 7 5 amp 5 amp Standard 40 60 90 120 150 5 amp 10 amp 15 amp 20 amp 25 amp 2 5 amp 5 amp 7 5 amp 10 amp 12 5 amp For other wattage motors...

Страница 9: ...rd all plastic closures on the Liquid End and align pump connections as dictated by your overall system design 2 Connect the suction check valve to a gravity fed chemical source This pump requires a f...

Страница 10: ...the power is connected To avoid this fit an On Off isolating switch between the timer s Motor Terminals on the PTH and the motor s terminals Fuses It is very important that the correctly sized fuse i...

Страница 11: ...s at different times days of week On Time Sets the On Time in seconds used in Fixed Mode 2 1 60 Off Time Sets the Off Time in seconds used in Fixed Mode 10 1 60 Flow Rate Sets the desired flow rate in...

Страница 12: ...re the controller has power on and the display shows as per on the previous page 2 Depress the twice or until the display shows OPTIONS and then depress the Select button 3 Depress the or buttons unti...

Страница 13: ...f it was on OPERATION cont 1 Power On LCD DISPLAY When rotating indicates Controller is running Clock Indictaes operation Start Timer Depress Select button to quick start Controller from this screen B...

Страница 14: ...st effective robust capable of operating at more extreme ambients and has been found to use less energy per volume of chemical injected Solar Injection Australia manufactures a range of DC Timers plea...

Страница 15: ...n in any way they should be replaced immediately with new parts available from Solar Injection Australia or SiA Distributors 6 Place the Crank Shaft and Bearings or replacement Bearings into the Drive...

Страница 16: ...nd chemical compatibility is paramount Our standard plunger seal TS is a specially formulated PTFE and stainless steel compound that is energized with a Viton o ring which is compatible with most chem...

Страница 17: ...LDC Motor To inspect and or replace brushes on our Standard PMDC Gearmotor models please follow the steps below 1 Disconnect power to pump before any servicing takes place 2 Use large flat blade screw...

Страница 18: ...Check seal if swollen check chemical compatibility and replace Check selection and ensure discharge line is not blocked Check and replace fuse in DC supply If this condition repeats itself check the d...

Страница 19: ...Barium Chloride C C C B A A A A A Barium Sulfite B A A A A A A A Benzaldehyde B A A A A C C C Benzene A A A A A C B C C Benzene Sulfonic Acid lO C B B A A A A C C Benzoic Acid C B B A A A C A Benzoyl...

Страница 20: ...C C B A A A A Copper Fluoride C B B B A A Copper Nitrate C B A A A A A A A Copper Sulfate B A A A A A A A A Cottonseed Oil A A A A A A A A Creosols A A A A A C C C A Cyclohexane B A A A A C A C A Cyc...

Страница 21: ...A A A Magnesium Carbonate A A A A A A A A Magnesium Chloride C B B A A A C A Magnesium Nitrate A A A A A A A A Magnesium Sulfate B A A A A A A A MaleicAcid Dilute C B A A A A A C Melamine Resins C B B...

Страница 22: ...Sodium Acetate B A A A A C B C Sodium Aluminate B A A A A A B A A Sodium Bicarbonate B A A A A A A A A Sodium Bichromate B A A A A A A Sodium Bifluoride Slurry A A A C Sodium Bisulfate B A A A A A A...

Страница 23: ...Tetrachloride Dry A A A A A A B C Toluene A A A A A C B C C Tributyl Phosphate B A A A A C C C Trichloroethylene Dry A A A A A C A C Tricresyl Phosphate B A A A A C B C A Triethanolamine A A A A B C A...

Страница 24: ...e needed Our timers controllers and detection accessories give our customers unparalleled control of the pumps both onsite and remotely via SCADA With our network of distributors we design and deliver...

Отзывы: