15) IP Settings
Displays the network settings for each port:
• Auto: For automatic DHCP or Link-Local IP addresses
• Manual: For Static IP addresses
16) Network Speed
Indicates the speed of the network.
17) Dante Latency
The latency setting for Dante devices should be set according to the
number of switches in the network. The SCM820 network card has an
internal switch chip and counts as a switch. For example, one SCM820
connected to an external switch equals two switches.
See Latency section for more details.
Software
18) Default Language Selection
Determines the language of the GUI when it opens on a computer with
no prior cookies.
19) Password
By default, no password is required to log on to the GUI. To add an
Administrator password for the GUI, follow these steps:
1. Enter password into the New Password field
2. Repeat for the Password (Confirm)
3. Select Apply to set the password.
Once a password is set, any user can log on as a Guest to view the
GUI without changing settings.
To clear a password and allow anyone full editing rights:
4. Log on to the GUI
5. Enter the current password into the Old Password text field.
6. Press the Clear button.
20) Load Settings Button
Uploads a file of saved settings to the device. This reconfigures the
IntelliMix settings of all units in a Link Group.
21) Save Settings Button
Select the Save Settings button to save the mixer settings (configuration
of the Input, IntelliMix, Output and Preferences tabs). Note: Link Group
and IP settings are not saved.
22) No Lights Mode
Turns off all visual indicators on the mixer (except the Power LED on the
front panel).
24) Reset
Returns the mixer to default factory settings (clearing the password and
device and channel names). The mixer will reboot in Standalone mode.
2
5)
Register This Product
Links to Shure website for product registration.
2
6)
Event Log Link
Links to the device’s Event Log, which opens in a new browser tab or
window. The log displays a list of all informational system events.