4. Use the arrow keys to move the ► to select
OK
to save or
Cancel
to
discard, and then press the
SET
key.
IP Address Mode:
Manual
Use manual IP addressing to set the IP address and subnet mask when a
DHCP server is not available.
1. Navigate to the IP mode menu and press the
SET
key.
2. Use the arrow keys to highlight
Manual
.
3. Press the
SET
key to enable editing of the IP address and the subnet
mask.
4. Use the arrow keys to move the ► to select
IP:
or
Sub:
5. Use the arrow keys and the
SET
key to edit the IP address and subnet
mask.
6. Use the arrow keys to move the ► to select
OK
to save or
Cancel
to
discard, and then press the
SET
key.
MAC
(MAC Address)
Displays the MAC address, which is an embedded, uneditable identification
number unique to each device. Used by the network and WWB software to
identify components.
Display Invert
This changes the LCD menu from white text on dark background to dark text
on a light background.
Firmware
Displays the version of firmware installed on this device.
Fan
(Cooling Fan Mode)
Automatic
The fan is enabled and adjusts speed based on the internal temperature of
the unit.
Always on
The fan runs continuously at maximum speed to provide maximum cooling
in warm environments.
Serial Number
Displays the serial number.
Brightness
Sets the brightness of the LCD to low, medium, or high.
Storage Mode
OFF
Normal charge.
Store at 3.8 V
Charges or discharges all batteries to bring them to a 3.8 volts, ideal for long
term storage.
Troubleshooting
Battery is inserted incorrectly or battery cannot
accept a charge. Check battery temperature.
Charge status LED does not
illuminate.
Battery discharged below 3.0 volts. Try another
battery.
Battery does not charge
Service Fans Maintenance Message
The charger displays the
Service Fans
message when the fans are unable
to cool efficiently.
•
Press any key to suppress the message for 20 seconds.
•
Service the fans or increase ventilation to the unit to clear the message.
Ÿ
Ÿ
SET
Service
Fans
Firmware Updates
Firmware is embedded software in each component that controls functional-
ity. Periodically, new versions of firmware are developed to incorporate addi-
tional features and enhancements. To take advantage of design improve-
ments, new versions of the firmware can be uploaded and installed using
the Firmware Update Manager tool available in WWB6 software. Firmware
is available for download from .
Specifications
Battery Type
Up to 8 rechargeable Li-Ion batteries (AXT910/920/920SL)
Charge Time
50%=1 hour; 100%=3 hours
Charging Module Type
Up to 4 charging modules (AXT901 or AXT902) in any combination
Operating Temperature Range
-18°C (0°F) to 63°C (145°F)
Battery Charging Temperature Range
0°C (32°F) to 60°C (140°F)
Shure Incorporated
AXT900
Rack Mount Charging Station
5/7
2017/10/10