Group and Channel

A group is a set of compatible frequencies. A single 

frequency within a group is a channel. 

G:

Change the group

Ch:

Change the channel

Frequency

Manual frequency selection in 25 kHz increments.

Gain

Sets the input sensitivity level (gain). Gain range is 

-10 to +40 dB in 1 dB steps.

RF Mute

Disables the RF carrier signal, which mutes transmis-

sion of audio. 

TX On:

RF signal enabled

TX Off:

RF signal disabled

Unlink

Ends the Link relationship between transmitter and 

receiver. 

YES:

Ends the Link between transmitter and receiver. 

NO:

Preserves the Link between transmitter and 

receiver. 

Note:

 When a transmitter is unlinked, the channel 

name reverts to 

Unlinked

ShowLink Test

Activates the ShowLink test 5-bar display. Measures 

the remote control range of a ShowLink Access Point. 

• 

5 bars indicate the center of the coverage area 

• 

1 bar indicates the outer boundary of the 

coverage area 

• 

If bars are not displayed, ShowLink control is 

not available 

Firmware

Displays the installed firmware version. 

Device ID

Identifies the transmitter on a linked receiver or in 

WWB software. 

• 

ID length can be up to 8 characters 

• 

Use arrow buttons to scroll through characters 

• 

Use 

set

 button to save and move to the next 

character 

AA Type

This setting ensures accurate battery metering when 

using the optional AA battery carrier. Set the battery 

type to 

Alkaline

NiMH

, or 

Lithium

Note: 

Menu not displayed unless an AA battery car-

rier is installed.

RF PWR

Sets RF power level. Access this menu by pressing 

and holding the 

set

 button and then pressing the ▼ 

button. 
Use lower power settings to conserve battery life and 

to prevent RF overload at the receiver. 

Note: 

A password is required in some regions. 

PCB Serial Number

Displays the serial number of the printed circuit board 

(PCB) installed in the unit. 
1.  Enter the 

RF PWR

 menu by pressing and holding 

the 

set

 button, and then pressing the ▼ button. 

2. 

Press the ▲ button to access the serial number. 

3.  Momentarily press the power button to return to 

the home menu screen. 

Troubleshooting 

Input Overload 

The 

Input Overload

 message indicates an excessive signal level at the transmitter 

input. To prevent overload, reduce the gain setting. 

No ShowLink Alert

Deeply Discharged Batteries

Deep discharge occurs when a battery is discharged to less than 3.0 volts. The 

battery chargers have a recovery mode designed to restore charge to a deeply dis-

charged battery. 
When the charger detects a deeply discharged battery, it automatically enters recov-

ery mode which supplies reduced current to the battery for up to 30 minutes. 
If recovery is successful, the charger will exit recovery mode and charge the battery 

to capacity. If the battery cannot be recharged, charging stops and the battery must 

be replaced.

Parameter Menus 

Use the arrow buttons to access the following parameter menus.

This alert appears when frequency is edited on a linked transmitter that is beyond 

the range of an active ShowLink access point. Choose 

OK

 to unlink the transmitter 

and complete the frequency change, or 

Cancel

 to return to the home screen.

Firmware Updates 

Firmware is embedded software used to control features and the user interface. Periodically, new versions of firmware are available for download from www.shure.com/wwb to 

incorporate additional features and enhancements. New versions of the firmware can be downloaded to AXT400 Receiver using the Firmware Update Manager tool available 

in WWB6 software and installed on the transmitter using the infrared ports on the transmitter and receiver.
To access the AXT400 receiver firmware update menu: 

Tx > IR Presets > FW Update

Содержание Axient

Страница 1: ...AXT100 Bodypack Transmitter 2011 Shure Incorporated 27B15017 Rev 2 Printed in USA...

Страница 2: ...pen crush modify disassemble heat above 140 F 60 C or incinerate Follow instructions from manufacturer Never put batteries in mouth If swallowed contact your physician or local poison control center D...

Страница 3: ...s Infrared IR Port Use for automated transmitter programming Links transmitter to AXT400 Receiver Power Button Hold for 1 second to turn the transmitter on To power off press and hold for 2 seconds un...

Страница 4: ...he power set and arrow buttons cannot be used to change transmitter settings The battery must be removed to access the switch Linking a Transmitter using IR Sync The IR Sync function forms a Link and...

Страница 5: ...erialNumber Displays the serial number of the printed circuit board PCB installed in the unit 1 Enter the RFPWR menu by pressing and holding the set button and then pressing the button 2 Press the but...

Страница 6: ...e Dimensions 77 mm x 66 mm x 17 mm 3 0 in x 2 6 in x 0 7 in H x W x D with AXT910 battery Weight 146 6 g 5 2 oz with batteries Housing Cast aluminum Operating Temperature Range 18 C 0 F to 63 C 145 F...

Страница 7: ...ble below offers a comparison of the output gain at the XLR output for AXT400 and UR4 receivers for each transmitter model Use the information in the table to achieve consistent gain levels when using...

Страница 8: ...or contact information please visit www shure com The CE Declaration of Conformity can be obtained from www shure com europe compliance Authorized European representative Shure Europe GmbH Headquarter...

Страница 9: ...ail info shure com hk United States Canada Latin America Caribbean Shure Incorporated 5800 West Touhy Avenue Niles IL 60714 4608 USA Phone 847 600 2000 Fax 847 600 1212 USA Fax 847 600 6446 Email info...

Отзывы: