background image

Safety

2

For parts or assistance, call SHUR-DRI Customer Service at 

1-800-535-4950

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury.

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

can 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The label 

NOTICE 

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

1. Read this manual carefully. Failure to follow these

Instructions could cause serious bodily injury and/or
property damage.

2. Consult installer or licensed plumber for correct relief

valve. Install system according to local codes. 

3. Always test water from well for purity before using.

Check local health department for testing procedure.

4. Before installing or servicing tank, BE SURE pump

electric power source is disconnected. Release all
water pressure before working on tank or system.
Release air pressure before removing cover flange.

5. Install relief valve in pump supply line to tank, as

close to tank as possible.

6. BE SURE pump electrical circuit is properly grounded.
7. Remove bleeder orifices, air volume controls or other

air charging devices in existing system.

8. DO NOT USE tank as a surge suppressor.

Hazardous pressure. To prevent possible

serious or fatal injury and/or damage to equipment, sys-
tem pressure must be less than 100 pounds per square
inch (PSI) (689kPa) under any circumstances. Failure to
follow instruction can result in tank blowup. If system
discharge pressure can exceed 100 PSI (689kPa), install
a relief valve capable of passing the full pump volume at
100 PSI (689kPa).

Do not allow pump, tank, or piping system

to freeze. Freezing can severely damage equipment and
may lead to tank explosion and serious injury. Allowing
tank to freeze voids tank warranty.

SHUR-DRI warrants to the original consumer purchaser (“Purchaser”) of its
products that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase
any such product shall prove to be defective, it shall be repaired or replaced at
SHUR-DRI’s option, subject to the terms and conditions set forth below. Your
original receipt of purchase is required to determine warranty eligibility.

Exceptions to the Twelve (12) Month Warranty

Two (2) Year Warranty:

If within two (2) years from original consumer purchase Models SDAS3 or
SDVS3 shall prove to be defective, it shall be repaired or replaced at 
SHUR-DRI’s option, subject to the terms and conditions set forth below.

Three (3) Year Warranty:

If within three (3) years from original consumer purchase Model SDAS5 shall
prove to be defective, it shall be repaired or replaced at SHUR-DRI’s option,
subject to the terms and conditions set forth below.

Five (5) Year Warranty:

If within five (5) years from original consumer purchase any Pre-Charge water
system tank shall prove to be defective, it shall be repaired or replaced at
SHUR-DRI’s option, subject to the terms and conditions set forth below.

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to replace prod-
uct covered by this warranty. This warranty shall not apply to acts of God, nor
shall it apply to products which, in the sole judgement of SHUR-DRI, have
been subject to negligence, abuse, accident, misapplication, tampering, alter-

ation; nor due to improper installation, operation, maintenance or storage; nor
to other than normal application, use or service, including but not limited to,
operational failures caused by corrosion, rust or other foreign materials in the
system, or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the
defective product to the Retail outlet or to SHUR-DRI as soon as possible
after the discovery of any alleged defect. SHUR-DRI will subsequently take
corrective action as promptly as reasonably possible. No requests for service
under this warranty will be accepted if received more than 30 days after the
term of the warranty.
This warranty sets forth SHUR-DRI’s sole obligation and purchaser’s exclusive
remedy for defective products.
SHUR-DRI SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDEN-
TAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL
OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND
BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or conse-
quential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusions may not apply to you. This warranty gives you
specific legal rights and you may also have other rights which vary from state
to state.

SHUR-DRI Limited Warranty

SHUR-DRI PUMP COMPANY • 1101 Myers Parkway • Ashland, OH U.S.A. 44805

Phone: 1-800-535-4950 • Web: http://www.shur-dri.com

Содержание SDPT119

Страница 1: ...LAND OH 44805 SD490 1 26 05 INSTALLATION MANUAL PRE CHARGED PRESSURE TANKS Pages 2 6 FRENCH INSTALLATION MANUAL RÉSERVOIRS À PRESSION PRÉCHARGÉE Pages 7 11 SPANISH INSTALLATION MANUAL TANQUES DE PRESION PRECARGADA Pages 12 16 CONSUMER HOT LINE 1 800 535 4950 Monday Friday 7 AM to 5 PM EST ...

Страница 2: ...l receipt of purchase is required to determine warranty eligibility Exceptions to the Twelve 12 Month Warranty Two 2 Year Warranty If within two 2 years from original consumer purchase Models SDAS3 or SDVS3 shall prove to be defective it shall be repaired or replaced at SHUR DRI s option subject to the terms and conditions set forth below Three 3 Year Warranty If within three 3 years from original...

Страница 3: ...ch cannot be more than 10 3M apart NOTICE Tank capacity is different than drawdown Tank capacity is the actual physical volume of the sheet metal that makes up the tank OPERATING CYCLE FIGURE 2 Step 1 Tank nearly empty air expands filling area above water cell Figure A Step 2 Water enters tank air is compressed above water cell as it fills with water Figure B Step 3 Pump up cycle completed air com...

Страница 4: ...essure may increase This may reduce tank drawdown amount of water available per cycle If this occurs adjust pre charge pressure accord ing to Chart 1 page 3 Flush all air out of piping system and water reservoir por tion of pre charged tank Required on new installations pumps requiring repriming and pumps disassembled for service Do as follows Step 1 Open faucets furthest from tank and run pump St...

Страница 5: ...CE Most standard tanks have separate inlet and outlet ports Pre charge tanks have one port serving both functions When replacing standard tank with a pre charge tank run pipe from pump into a tee as shown 2nd leg of tee goes to tank elbow 3rd leg goes to exist ing service To service Pressure Relief Valve Pressure Gauge Pressure Switch From Well Figure 5 Typical installation with vertical pre charg...

Страница 6: ...446P U31 446P U31 446P U31 447P U31 447P U231 462P 3 Flanged Nut 5 16 18 Hex 6 U36 202BT U36 202BT U36 202BT U36 202BT U36 202BT U36 202BT 4 Air Valve with Cap 1 U212 160 U212 160 U212 160 U212 160 U212 160 U212 160 REPAIR PARTS LIST Standard hardware items may be purchased locally 1 2 3 4 2399 0496SRS For parts or assistance call SHUR DRI Customer Service at 1 800 535 4950 ...

Страница 7: ...ectueux dans les douze 12 mois qui suivent la date d achat d origine sera remplacé ou réparé à la discrétion de SHUR DRI selon les conditions stipulées ci dessous La preuve d achat est exigée pour déterminer l ad missibilité à la garantie Exceptions à la garantie de douze 12 mois Garantie de deux 2 ans Si dans les deux 2 ans à compter de la date de son achat par le premier acheteur un modèle SDAS3...

Страница 8: ...e peuvent pas être installés à plus de 10 pieds 3 mètres l un de l autre NOTA La capacité du réservoir n est pas la quantité d eau pouvant être soutirée La capacité du réservoir est le volume physique réel de la tôle qui compose le réservoir CYCLES DE FONCTIONNEMENT FIGURE 2 1 Le réservoir est presque vide l air remplit la partie qui se trouve au dessus du diaphragme Figure A 2 L eau commence à re...

Страница 9: ...précharge conformément au Tableau 1 de la page 7 Chasser tout l air des tuyauteries du système et de la partie réservoir d eau du réservoir préchargé Ceci est obligatoire dans le cas d installations neuves de pompes devant être réamor cées et si la pompe a été démontée pour être réparée Pour procéder à cette opération 1 Ouvrir les robinets qui se trouvent les plus loin du réservoir et démarrer la ...

Страница 10: ... comportent des ori fices d arrivée et de sortie séparés Les réservoirs préchargés comportent un orifice qui sert à ces deux fonctions Lorsque l on remplace un réservoir standard par un réservoir préchargé brancher le tuyau provenant de la pompe dans un té comme il est illustré La 2e branche du té servira à brancher un tuyau sur le coude du réservoir et la 3e branche du té servira à brancher la tu...

Страница 11: ...T85 SDPT119 1 Diaphragme en vinyle 1 U20 13 U20 13 U20 9 U20 10 U20 14 U20 20 2 Bride du couvercle 1 U31 446P U31 446P U31 446P U31 447P U31 447P U231 462P 3 Écrou à bride 5 16 18 6 U36 202BT U36 202BT U36 202BT U36 202BT U36 202BT U36 202BT 4 Valve avec chapeau 1 U212 160 U212 160 U212 160 U212 160 U212 160 U212 160 PIÈCES DE RECHANGE Articles standard à acheter localement 1 2 3 4 2399 0496SRS ...

Страница 12: ...compra cualquiera de los productos demostrara estar defectuoso el mismo será reparado o reemplazado a opción de SHUR DRI con sujeción a los términos y condiciones expuestos a conti nuación Se requiere su recibo original de compra para determinar si se encuentra bajo garantía Excepciones a la Garantía por Doce 12 Meses Garantía de dos 2 años Si dentro de los dos 2 años de la compra por el consumido...

Страница 13: ...ancia AVISO La capacidad del tanque es diferente de la aspiración adicional La capacidad del tanque es el volumen físico efecti vo de la hoja de metal que forma el tanque CICLO DE OPERACIÓN FIGURA 2 Paso 1 El tanque está casi vacío el aire se xpande llenando el área por encima de la cisterna Figura A Paso 2 El agua entra en el tanque el aire se comprime por encima de la cisterna a medida que se ll...

Страница 14: ... la porción del depósito de agua en el tanque precargado Esto se requiere en nuevas instalaciones bombas que se deben volver a cebar y bombas que se han desarmado para servicios de mantenimien to o reparaciones Se debe realizar lo siguiente Paso 1 Abra los grifos más lejanos al tanque y haga funcionar la bomba Paso 2 Haga funcionar la bomba hasta que no haya más chis porroteo y se observe una corr...

Страница 15: ...oría de los tanques tiene orificios separados de entrada y de salida Los tanques precargados poseen un orifi cio para ambas funciones Cuando sustituya un tanque están dar con un tanque precargado haga correr un tubo desde la bomba hacia el tubo en T según se ilustra La segunda pata del tubo en T va al codo del tanque la tercera pata va al servicio ya existente ADVERTENCIA To service Pressure Relie...

Страница 16: ...a vinilo 1 U20 13 U20 13 U20 9 U20 10 U20 14 U20 20 2 Reborde cobertor 1 U31 446P U31 446P U31 446P U31 447P U31 447P U231 462P 3 Tuerca de bridas 5 16 18 6 U36 202BT U36 202BT U36 202BT U36 202BT U36 202BT U36 202BT 4 Valvula de aire con tapa 1 U212 160 U212 160 U212 160 U212 160 U212 160 U212 160 REFACCIONES Artículos estándar de ferretería se pueden adquirir a nivel local 1 2 3 4 2399 0496SRS ...

Отзывы: