Safety
2
SAFETY INFORMATION
Use Model SD106 only on a
115 volt circuit. Model
SD106 is equipped with an
approved 3-conductor cord and 3-prong,
grounding-type plug. To reduce the risk of
electric shock, connect it to a properly
grounded, grounding-type receptacle.
If circuit has a 2-prong receptacle, replace
it with a properly grounded 3-prong recep-
tacle installed in accordance with the
National Electrical Code and local codes
and ordinances.
Any extension cord used must be outdoor
grade, gauge 16 AWG or heavier, and not
more than 25’ long.
Risk of fire or explosion if
used to pump flammable liquids or if used
in explosive atmospheres.
Pump water
only with this pump. Pump is designed
to pump water at temperatures between
32°-77° F (0°-25° C) only.
Risk of electrical shock. Do
not allow the motor to get wet!
Risk of burns.
During
normal operation, motor will normally run
hot enough to burn you. Do not touch
motor when it is hot.
Do not operate the pump continuously at a
discharge pressure of more than 12 psi
(83 kPa) or discharge lift of more than
28’ (8.5 M), as the motor will exceed the
normal safe operating temperature and
may heat to 180° - 190° F (82° C - 88° C).
Pump water only with this pump.
NOTICE:
This unit is not designed as a water-
fall or fountain pump, or for applications
involving salt water or brine! Use with water-
falls, fountains, salt water or brine will void
warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool
drainer.
Hazardous
voltage
Содержание SD106-01