![Shuangri Electron SR258 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/shuangri-electron/sr258/sr258_operation-manual_1260877036.webp)
Manual of SR258 intelligent controller
35
OSTC (Tank cooling function) setting
►Press “▲” button, “OSTC” displays on the screen
►Press “SET”, “OSTC OFF” displays on the screen
►Press “SET” button, “OFF” blinks
►Press “▲/▼” to activate this function
►Press “▲”, “DTCO 20K” displays on the screen
►Press “SET”, “20K” blinks
►Press “▲/▼”, to adjust the switch on temperature difference
►Press “SET” or “ESC” to save the setting
►Press “▲”, “DTCF 15K” displays on the screen
►Press “▲/▼”, to adjust the switch-off temperature difference
►Press “SET” or “ESC” to save the setting
►Press “ESC” to return to previous menu
OHDP (Heat transferring) setting
►Press “▲”, “OHDP” displays on the screen
►Press “SET”, “OHDP OFF” displays
►Press “SET”, “OFF” blinks”
►Press “▲/▼”, to activate this function, “OHDP ON” displays
►Press “▲”, “OTST 80
o
C” displays
►Press “SET”, “80
o
C” blinks
►Press “▲/▼”, to adjust the temperature of heat transferring
►Press “SET” or “ESC” to save the setting
►Press “▲” button, “OTPM ON” displays
►Press “SET”, “ON” blinks
►Press “▲/▼”, to select the control logic pump or valve
►Press “SET” or “ESC” to save the setting
►Press “▲”, “REL 3” displays
►Press “SET”, “3” blinks
►Press “▲/▼”, to select the output port for heat transferring
►Press “SET” or “ESC” to save the setting
►Press “ESC” to return to previous menu
7.6 AUX Auxiliary function
Function description: